Results 31 to 40 of about 1,462,184 (202)
Appropriate methods to analyse power conversion harmonics [PDF]
Nowadays, non-linear loads represent the majority of the residential electrical consumers. The limits on emission and immunity are imposed by IEC- standards, however there is a lack in the domain 2 – 150 kHz.
P. Verzele +8 more
core +2 more sources
This paper presents the details of the development, evaluation process, and results of linear and nonlinear time-invariant models used to represent the frequency response of inductive high-voltage instrument transformers.
Imanka Dewayalage +3 more
doaj +1 more source
Continuous harmonic analysis and power quality measurements in three-phase systems [PDF]
A virtual instrument, named Power Quality Meter, is presented for (a) measuring power consumption and harmonics in three-phase systems, under non-sinusoidal and imbalance conditions (b) detecting, classifying and organizes power disturbance events ...
Bravo-Rodríguez, Juan Carlos +6 more
core +1 more source
Solar PV inverters require output filters to reduce unwanted harmonics in their output, where LCL filters are a more economical choice than larger inductance-only filters. A drawback of these filters is that they can introduce power quality disturbances,
Kasun Peiris +3 more
doaj +1 more source
Measurement of High-Frequency Voltage Harmonics above 2 kHz in High-Voltage Networks
Large-scale renewable energy plants, flexible AC (alternating current) and high voltage DC (direct current) transmission systems, and modern consumer devices utilize power electronics that tend to increase harmonic emissions.
Imanka Dewayalage +3 more
doaj +1 more source
Study on the pyrolysis characteristics of styrene-grafted polypropylene cable insulation material
Polypropylene (PP) has garnered significant attention as a cable insulation material due to its exceptional electrical performance and recyclability. Styrene-grafted polypropylene (PP-g) emerges as a promising alternative in this context.
Chao Peng +7 more
doaj +1 more source
Safe Operation Area of Energy-Storage-Free Dynamic Voltage Restorer
Energy-storage-free dynamic voltage restorer (DVR) is a common device used to solve voltage sag problems in engineering, but its actual operation is limited by the parameters of application scenarios.
Mingxing ZHU +3 more
doaj +1 more source
Electrical losses in multi-MW wind energy conversion systems [PDF]
Publisher Copyright: © 2012, European Association for the Development of Renewable Energy, Environment and Power Quality (EA4EPQ). All rights reserved.This paper proposes a procedure to assess the electrical losses in Wind Energy Conversion Systems ...
Martínez de Alegría, I. +9 more
core +2 more sources
High-resolution multi-channel digitizers are used extensively for precision low voltage measurements in numerous applications and allow the simultaneous measurement of voltage magnitude ratio and phase difference between two different waveforms in power ...
Imanka Dewayalage +3 more
doaj +1 more source
Hamiltonian energy‐balance method for direct analysis of power systems transient stability
This paper outlines a Hamiltonian energy‐balance function for computing stable and unstable regions of power systems. Once the generator model is defined, a certain number of variables (holonomic constraints) specifies its state properties (prefault ...
Emanuelle Machado +1 more
doaj +1 more source

