Results 101 to 110 of about 82,174 (302)
Transients in no-load condition of power transformer 20/0,4 kV [PDF]
Ovaj rad predstavlja inovativan pristup u analizu prijelaznih pojava u elektroenergetskom sustavu korištenjem novopredloženih načina obrade podataka dobivenih iz procesora ugrađenog u moderne zaštitne releje u elektroenergetskom sustavu.
Damir Crnković +2 more
core +1 more source
Cognitive Behavioral Therapy for Youth with Childhood‐Onset Lupus: A Randomized Clinical Trial
Objective Our objective was to determine the feasibility and acceptability of the Treatment and Education Approach for Childhood‐onset Lupus (TEACH), a six‐session cognitive behavioral intervention addressing depressive, fatigue, and pain symptoms, delivered remotely to individual youth with lupus by a trained interventionist.
Natoshia R. Cunningham +29 more
wiley +1 more source
This paper focused to determine the performance of Current Transformer (CT) operates under harmonics condition and their effects on transformer differential protection. A laboratory test has been implemented to determine the error produced by both CT and
Nisja Indra
doaj +1 more source
Релейная защита и автоматика Беловской ГРЭС [PDF]
Выпускная квалификационная работа, состоящая из 75 страниц, 9 рисунков, 17 таблиц, 9 источников, 2 приложений. Ключевые слова: релейная защита, короткое замыкание, трансформатор, уставка.
Ващенко, Ксения Вячеславовна
core
Mesoporous bioactive glass nanoparticles (MBGNs) are investigated for bone regeneration given their remarkable structural and functional properties. MBGNs are functionalized with Mn and Cu and incorporated with quercetin, a natural flavonoid exhibiting antioxidant, anti‐inflammatory, and antimicrobial properties.
Giovanni Lo Bello +5 more
wiley +1 more source
Research of lightning protection gap of 35 kV power line of coal mine
In order to test lightning protection effect of protection gap for 35 kV power line, the paper simulated lightning invasion in 35 kV transformer taking 35 kV overhead line of a mine as model by use of ATP-EMPT electromagnetic transient analysis software,
DENG Jie-wen +5 more
doaj
The normal operation of the main transformer in the photovoltaic power station is the basis for the power generation output, however, the magnetizing inrush current may lead the differential protection of the transformer to malfunction.
LUAN Yunfei +4 more
doaj +1 more source
This study investigates laser shock peening for enhancing fatigue performance of riveted aerospace aluminum joints. A comparative approach with cold expansion combines fatigue testing and synchrotron X‐ray methods. Integrating mechanical testing with residual stress and strain characterization provides insights into how different treatments affect the ...
Ogün Baris Tapar +6 more
wiley +1 more source
Voltage Distribution on Transformer Windings Subjected to Lightning Strike Using State-Space Method
Transient analysis in power systems is essential for identifying deficiencies in the system, as well as for the protection and design of equipment. Transients can arise from natural events or network operations; in either case, they have the potential to
İlker Arı, Mehmet Salih Mamiş
doaj +1 more source
An idea of designing novel sensors is proposed by creating appropriate Schottky barriers and vacancies between isomorphous Core‐CuOii/ Shell‐CuOi secondary microspheres and enhancing catalytic and spill‐over effects, and electronegativity via spontaneous biphasic separation, self‐assembly, and trace‐Ni‐doping.
Bala Ismail Adamu +8 more
wiley +1 more source