Fault slip can occur ahead of the injection pressure front due to poroelastic stress. Our model captures the interaction of pressure, stress, and friction, providing new insights into injection‐induced seismicity and post‐injection fault slip. Shut‐in operations can either mitigate or accelerate seismic events depending on fault conditions and ...
Qifeng Xie, Lei Wang, Qi Li
wiley +1 more source
Flexural Behavior of Partially Pretensioned Continuous Concrete Beams
This paper describes flexural behavior of two spans continuous rectangular concrete beams reinforced with mild steel and partially prestressing strands, to evaluate using different prestressing level and prestressing area in continuous prestressed beams ...
Nazar Kamil Oukaili +1 more
doaj +2 more sources
To investigate the effects of long-term prestress loss on concrete box girders strengthened with external prestressing, a large-span box girder, in service for over 20 years and strengthened with external prestressing, was monitored for four months. Prestress loss in the longitudinal, vertical, and transverse directions of the box girder was calculated
Haoran Guo +4 more
openaire +3 more sources
This study presents large‐scale similarity model testing (geometric ratio 3.6) of an innovative multiple‐layered lining system—comprising exterior precast segments, middle self‐compacting concrete, and an interior steel pipe—for high‐pressure (0.75 MPa) water conveyance tunnels.
Ramin Asadi +4 more
wiley +1 more source
Evaluation of prestress losses in concrete beams using destructive and non‐destructive methods
Abstract Over the past few decades, prestressing techniques have become essential in the construction of key structures, infrastructure, and bridges. The serviceability and safety of prestressed concrete (PC) elements are closely tied to the effectiveness of the prestressing process.
A. N. Consiglio, G. Muciaccia, G. Rosati
wiley +1 more source
Large‐scale tests of 50‐year‐old prestressed concrete bridge girders
Abstract An experimental investigation has been carried out as part of the BRIDGE|50 research project, focusing on large‐scale loading tests performed on five 50‐year‐old prestressed concrete (PC) girders. The study aimed at evaluating the structural response of five girders retrieved from a viaduct in the urban area of Turin, Italy, subjected to 4 ...
Francesco Tondolo +7 more
wiley +1 more source
Abstract In practice, reinforced concrete (RC) wall‐like columns often have openings to facilitate building services, which creates stress concentrations around the opening, resulting in the weakening of their load‐carrying capacity. This study proposes innovative strengthening methods using near‐surface mounted (NSM) incorporating steel materials to ...
Ahmed Hamoda +4 more
wiley +1 more source
Fibres in living cells carry the pre-existing tension (so-called prestress) even without external loading. By changing the prestress, cells are able to control actively their overall mechanical response; it is therefore an important element in cell elasticity.
Vychytil J., Holeček M., Moravec F.
openaire +1 more source
Flexural performance of concrete‐filled steel tubular beams with wood chip aggregate
Abstract This study investigates the flexural performance of concrete‐filled steel tubular (CFST) beams with partial replacement of aggregates by wood chips (0%–25%) through experimental and numerical analysis. This study is novel in that it experimentally and numerically investigates the flexural behavior of CFST beams with partial replacement of ...
Mizan Ahmed +6 more
wiley +1 more source
Abstract Compression field approaches such as the Cracked Membrane Model with fixed, interlocked cracks (CMM‐F) are efficient tools for the mechanical modeling of reinforced concrete elements, providing the mechanical model σ=fε$$ \boldsymbol{\upsigma} =f\left(\boldsymbol{\upvarepsilon} \right) $$ required for finite element analyses.
Andreas Näsbom +2 more