Results 161 to 170 of about 211,981 (215)
A hybrid experimental-numerical framework for prestressed concrete bridge model validation and sensor placement optimization: a case study. [PDF]
Jayasinghe SC +8 more
europepmc +1 more source
Seismic performance evaluation of precast post-tensioned high-performance concrete frame beam-column joint under cyclic loading. [PDF]
Pang X, Li Y.
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Redevelopment of Prestressing Force in Severed Prestressed Strands
Journal of Bridge Engineering, 2011The flexural capacity rating of prestressed girders having severed or corroded strands often progresses by simply neglecting the contribution of the affected strands from the girder section and assessing the capacity. While this is an adequate approach at the affected section, it is conservative elsewhere along the span, assuming that fully bonded ...
Jarret Kasan, Kent A. Harries
openaire +1 more source
FATIGUE CHARACTERISTICS OF PRESTRESSING STRAND.
Proceedings of the Institution of Civil Engineers, 1972THIS PAPER PRESENTS THE RESULTS OF 189 FATIGUE TESTS CARRIED OUT ON 12.7 MM DIAMETER THERMALIZED SEVEN-WIRE PRESTRESSING STRAND. THE EFFECT OF TEST LENGTH AND/OR LATERAL PRESSURE ON THE FATIGUE LIFE AT VARIOUS STRESS AMPLITUDES IS REPORTED TOGETHER WITH AN INVESTIGATION OF THE EFFECTS OF ABRASION.
AD EDWARDS, A PICARD
openaire +1 more source
Development Length of Prestressing Strands
PCI Journal, 1977Based on an extensive literature survey of bond development, the authors propose a new equation for the transfer length of prestressing strand. This equation accounts for the effects of strand size, initial prestress, and concrete strength at transfer, and is applicable to concrete strengths ranging from 2000 to 8000 psi.
Talat Mostafa, Paul Zia
openaire +1 more source
Probabilistic Models for Mechanical Properties of Prestressing Strands [PDF]
Abstract This study focus on the probabilistic modelling of mechanical properties of prestressing strands based on data collected from tensile tests carried out in Laboratorio Nacional de Engenharia Civil (LNEC), Portugal, for certification purposes, and covers a period of about 9 years of production.
Luis Neves, Luciano Jacinto
exaly +3 more sources
Influence of corrosion on prestress strands
Canadian Journal of Civil Engineering, 1999Corrosion on prestress strands affects their mechanical properties as well as the coefficient of friction in the surface strand/duct. In previous research on prestress beams, the authors have observed different coefficients of friction depending on the surface condition of the strands and wires used in investigation.
S.M.R. Lopes, L.M.L.P. Simões
openaire +1 more source
Fatigue of Prestressed Concrete Beams with Inclined Strands
Journal of Structural Engineering, 1994This paper presents the results of laboratory cyclic testing of preten-sioned concrete beams with hold-downs operating in the cracked or partially prestressed condition. It is shown that the fatigue life of inclined strand is low due to flexural action in strand at cracks.
Muller J.F., Dux P.F.
openaire +3 more sources
Concrete Beams Prestressed with CFRP Strands
Structural Engineering International, 1997The behaviour of prestressed concrete beams reinforced with CFRP (carbon fibre reinforced plastic) strands was investigated and compared to prestressed concrete elements using conventional steel.
openaire +3 more sources

