Results 171 to 180 of about 211,981 (215)
Some of the next articles are maybe not open access.
Effect of Reduced Bond of Prestressed Strands
Solid State Phenomena, 2016Bond of prestressing strands may be reduced by using protective coatings against corrosion during winter period, when early grouting of ducts may be impossible. It was not verified if the reduced bond has an influence on the performance of the post-tensioned structures.
Jan L. Vítek, David Čítek
openaire +1 more source
Bond characteristics of untensioned prestressing strand
PCI Journal, 1977The bond behavior of untensioned prestressing strand was studied to evaluate load-deformation characteristics as well as load-embedment requirements. The results of the study are applicable to bonded untensioned strand as reinforcing for concrete in particular for connection between precast elements.
John R. Salmons, Timothy E. McCrate
openaire +1 more source
Transfer Control of Prestressing Strands
PCI Journal, 1992Based on a particular bond stress-slip relationship, nonlinear equations are developed for the transfer length and for the draw-in of prestressing strands taking into account the effective or the initial prestress, the concrete strength at transfer and the strand size. These equations can be used as the end block design of a prestressed concrete member
openaire +1 more source
Bond Modelling of Prestressing Strand
SP-180: Bond and Development of Reinforcement - A Tribute to Dr. Peter Gergely, 1998From pull-out and push-in tests on specimens with short embedment length an empirical relation has been derived, which describes the local bond stress as a function of the local slip and steel stress change. With the help of this bond model the transfer length and the bi-linear relationship for the development length of a pretensioned strand (ACI ...
openaire +1 more source
Construction and Building Materials, 2016
Prestressing of strengthening materials can enhance the performance of strengthened structures as the materials become more efficient as a greater portion of their tensile capacity is employed. Prestressed concrete beams are widely used in the construction field, however, there is a lack of studies on the strengthening of these structural elements ...
U Johnson Alengaram +2 more
exaly +3 more sources
Prestressing of strengthening materials can enhance the performance of strengthened structures as the materials become more efficient as a greater portion of their tensile capacity is employed. Prestressed concrete beams are widely used in the construction field, however, there is a lack of studies on the strengthening of these structural elements ...
U Johnson Alengaram +2 more
exaly +3 more sources
Pullout Capacity of Non-Prestressed Bent Strands for Prestressed Concrete Girders
PCI Journal, 2002In a recently concluded investigation on shear limits in precast, prestressed concrete girders for the Nebraska Department of Roads (NDOR), it was determined that the AASHTO LRFD limit for maximum shear reinforcement is attainable as long as an adequate number of strands is anchored into the abutment diaphragms.
Panya Noppakunwijai +4 more
openaire +1 more source
Transfer Length of Prestressing Strand as a Function of Draw-In and Initial Prestress
PCI Journal, 1993Guyon's formula expresses the transfer length of a prestressing tendon as a function of both the initial prestress and the draw-in. A modification of Guyon's formula is proposed which can take into account not only constant and linear behavior but also any nonlinear bond stress distribution over the transfer length.
openaire +1 more source
Bond Model for Prestressed Strands in Fire Exposed Concrete
High Performance Materials in Bridges, 2003This paper presents an elastoplastic bond-slip model for simulation of the anchorage behavior of prestressed strands in concrete structures under both ambient and fire conditions. The model allows for a detailed simulation of the slip and prestress development during fire.
Fellinger, J.H.H. +2 more
openaire +1 more source
Assessment of Bond Behavior of UHPC and Prestressing Strands
Advanced Materials Research, 2014Ultra High Performance Concrete - UHPC is a relatively new type of composite material with outstanding features (high compressive strength, high tensile strength and high durability). Also the bond strength between steel reinforcement and UHPC is better than that in ordinary concrete. This fact needs to be quantified, because no standard prescribes the
David Citek +4 more
openaire +1 more source
Influence of cover on bond of strands prestressed by pretensioning
Canadian Journal of Civil Engineering, 2001Cover of prestressed tendons is an important factor that influences the transmission of prestress by bond. This paper describes a study of the influence of cover on the bond behaviour of prestressed pretensioned strands. Ten beams with different cover values were produced and tested.
Ricardo N.F. do Carmo +1 more
openaire +1 more source

