Results 51 to 60 of about 211,981 (215)
Strand bond performance in prestressed concrete accounting for bond slip [PDF]
This paper presents the results of an experimental research program addressing the bond behavior of prestressing strands in pretensioned prestressed concrete members after anchorage failure has occurred. A test methodology based on measuring the prestressing strand force and strand end slip at the specimens free end was employed.
Martí Vargas, José Rocío|| +2 more
openaire +2 more sources
Molecular insights and translational opportunities to enhance heat tolerance in rice
Abstract Heat stress is an increasingly serious threat to rice (Oryza sativa L.) productivity, yet the genetic and regulatory architecture underlying thermotolerance remain poorly resolved and fragmented across studies. Earlier research focused on individual pathways or specific developmental stages; however, recent advances now support an integrated ...
Prabhat Rana +7 more
wiley +1 more source
This study aims to develop a prestressed concrete steel (PC) strand with an embedded optical Fiber Bragg Grating (FBG) sensor, which has been developed by the Korea Institute of Civil Engineering and Building Technology since 2013.
Sung-Tae Kim +4 more
doaj +1 more source
Evaluation of prestress losses in concrete beams using destructive and non‐destructive methods
Abstract Over the past few decades, prestressing techniques have become essential in the construction of key structures, infrastructure, and bridges. The serviceability and safety of prestressed concrete (PC) elements are closely tied to the effectiveness of the prestressing process.
A. N. Consiglio, G. Muciaccia, G. Rosati
wiley +1 more source
Large‐scale tests of 50‐year‐old prestressed concrete bridge girders
Abstract An experimental investigation has been carried out as part of the BRIDGE|50 research project, focusing on large‐scale loading tests performed on five 50‐year‐old prestressed concrete (PC) girders. The study aimed at evaluating the structural response of five girders retrieved from a viaduct in the urban area of Turin, Italy, subjected to 4 ...
Francesco Tondolo +7 more
wiley +1 more source
Pre‐failure behavior of continuous post‐tensioned and post‐grouted beam in case of tendon failure
Abstract Grouted tendons are a common solution for long‐span bridge structures. The grout provides bond and corrosion protection for prestressing steel. However, if the grouting is defective, corrosion of the prestressing steel may initiate and eventually lead to tendon failure.
Olli Asp +2 more
wiley +1 more source
Abstract Fault slip occurs in both seismic and aseismic styles with spatial variability across scales, yet non‐unique source inference limits our ability to resolve slip complexity and dynamics. Here we evaluate the effect of spatial smoothing regularization in Bayesian frameworks by comparing an unregularized (BUR) approach that samples distributed ...
Xiong Zhao, Junle Jiang
wiley +1 more source
A Test Method for the Transfer Length of Prestressing Strand in Hollow Core Slabs [PDF]
University of Minnesota M.S. thesis. June 2017. Major: Civil Engineering. Advisor: Arturo Schultz. 1 computer file (PDF); xii, 135 pages.A method for measuring the transfer length of prestressing strand in HCS using a distributed strain sensor (DSS) was
Robole, Jacob
core
The study elucidates that paternal preconception stress can drive offspring hyperresponsivity of the stress system via hypomethylation of a specific DNA region in sperm. This key link is confirmed in a cohort of prospective fathers: the epigenetic alteration is associated with elevated stress hormone levels.
Mengxi Lu +10 more
wiley +1 more source
An investigation of the variables affecting pullout of seven-wire prestressing strand [PDF]
The pullout strength of untensioned prestressing strand is a function of several variables. This study is an attempt to identify and isolate these variables.
Griffin, Ken Louis
core

