Results 31 to 40 of about 145 (133)

Investigation on the mechanical behavior of the multiple‐layered lining structure of a water conveyance tunnel with high internal water pressure

open access: yesDeep Underground Science and Engineering, EarlyView.
This study presents large‐scale similarity model testing (geometric ratio 3.6) of an innovative multiple‐layered lining system—comprising exterior precast segments, middle self‐compacting concrete, and an interior steel pipe—for high‐pressure (0.75 MPa) water conveyance tunnels.
Ramin Asadi   +4 more
wiley   +1 more source

Evaluation of prestress losses in concrete beams using destructive and non‐destructive methods

open access: yesStructural Concrete, EarlyView.
Abstract Over the past few decades, prestressing techniques have become essential in the construction of key structures, infrastructure, and bridges. The serviceability and safety of prestressed concrete (PC) elements are closely tied to the effectiveness of the prestressing process.
A. N. Consiglio, G. Muciaccia, G. Rosati
wiley   +1 more source

Transient response and performance of prestressed concrete deep T-beams with large web openings under impact loading

open access: yesJournal of the Mechanical Behavior of Materials, 2023
This study reports testing results of the transient response of T-shape concrete deep beams with large openings due to impact loading. Seven concrete deep beams with openings including two ordinary reinforced, four partially prestressed, and one solid ...
Abbas Rafaa M., Hussein Lara T.
doaj   +1 more source

Analysis of Long-Term Prestress Loss in Prestressed Concrete (PC) Structures Using Fiber Bragg Grating (FBG) Sensor-Embedded PC Strands

open access: yesApplied Sciences, 2021
This study aims to develop a prestressed concrete steel (PC) strand with an embedded optical Fiber Bragg Grating (FBG) sensor, which has been developed by the Korea Institute of Civil Engineering and Building Technology since 2013.
Sung-Tae Kim   +4 more
doaj   +1 more source

Large‐scale tests of 50‐year‐old prestressed concrete bridge girders

open access: yesStructural Concrete, EarlyView.
Abstract An experimental investigation has been carried out as part of the BRIDGE|50 research project, focusing on large‐scale loading tests performed on five 50‐year‐old prestressed concrete (PC) girders. The study aimed at evaluating the structural response of five girders retrieved from a viaduct in the urban area of Turin, Italy, subjected to 4 ...
Francesco Tondolo   +7 more
wiley   +1 more source

Pre‐failure behavior of continuous post‐tensioned and post‐grouted beam in case of tendon failure

open access: yesStructural Concrete, EarlyView.
Abstract Grouted tendons are a common solution for long‐span bridge structures. The grout provides bond and corrosion protection for prestressing steel. However, if the grouting is defective, corrosion of the prestressing steel may initiate and eventually lead to tendon failure.
Olli Asp   +2 more
wiley   +1 more source

Poisson's ratio and stress-transfer mechanism of triangular-shaped ten-wire prestressing strand [PDF]

open access: yesGrađevinski Materijali i Konstrukcije
This study investigates the Poisson's ratio and deformation behavior of a triangular ten-wire prestressing strand in comparison to conventional seven-wire strand.
Lazić Žarko   +2 more
doaj   +1 more source

Prestressed Concrete Box Girder with High-Capacity Strands-Monitoring and Analysis during Fabrication

open access: yesBuildings, 2022
Despite the attractive merits of high-capacity strands, the application in bridge girders is limited due to concerns, including concrete cracking, excessive stress, and cambers.
Xin Jiang   +6 more
doaj   +1 more source

Punching shear of unbonded post‐tensioned steel fiber reinforced concrete slabs: The fiber contribution

open access: yesStructural Concrete, EarlyView.
Abstract Steel fiber reinforced concrete (SFRC) enhances the flexural capacity of flat slabs and, due to its effectiveness in statically redundant bi‐dimensional elements, represents a viable alternative to conventional reinforcement. Although numerous studies have investigated the flexural behavior of SFRC slabs with and without bonded reinforcement ...
Chiara Gaddi   +2 more
wiley   +1 more source

Sensitivity study on accuracy and relevant parameters in numerical modeling of internal tendon breaks

open access: yesStructural Concrete, EarlyView.
Abstract This study investigates the numerical modeling of internal tendon breaks in prestressed concrete structures and evaluates the key parameters affecting accuracy. A combined approach is followed, involving global sensitivity analysis via the Elementary Effects Method and subsequent model calibration using experimental data from distributed fiber‐
Aeneas Paul, David Sanio, Peter Mark
wiley   +1 more source

Home - About - Disclaimer - Privacy