Results 31 to 40 of about 211,981 (215)
A Sensor-Type PC Strand with an Embedded FBG Sensor for Monitoring Prestress Forces
Prestressed Concrete Wire and Strand (PC) strands are the most used materials to introduce prestress in a Pre-Stressed Concrete (PSC) structure. However, it is difficult to evaluate the final prestress force of the PC strand after prestressing or its ...
Sung Tae Kim +4 more
doaj +1 more source
Temperature Compensation of Fiber Bragg Grating Sensors in Smart Strand
Compared to other types of sensors, fiber optic sensors have improved accuracy and durability. Recently, the Smart Strand was developed to maximize the advantages of fiber optic sensors for measuring the cable forces in prestressed concrete structures or
Se-Jin Jeon +2 more
doaj +1 more source
Abstract This study investigates the numerical modeling of internal tendon breaks in prestressed concrete structures and evaluates the key parameters affecting accuracy. A combined approach is followed, involving global sensitivity analysis via the Elementary Effects Method and subsequent model calibration using experimental data from distributed fiber‐
Aeneas Paul, David Sanio, Peter Mark
wiley +1 more source
Assessment of Partial Debonding Practice for AASHTO Type Girders [PDF]
Pretensioned girders have been commonly used in bridge construction for years. However, some problems remain that hinder the further application of longer and more heavily prestressed girders. The prestressing force can produce large stresses at both the
Wang, Weijin
core
Interlaboratory study of standard methods for testing multiwire steel prestressing strand [PDF]
An interlaboratory study involving 19 laboratories was conducted to quantify the precision of ASTM A1061-16, Standard Test Methods for Testing Multi-Wire Steel Prestressing Strand, which describes methods for measuring yield strength, elastic modulus ...
Lequesne, Rémy D. +9 more
core +1 more source
Mechanical Behaviors of Corroded Prestressing Strands
AbstractCorrosion will reduce the cross-sectional area of strands and deteriorate the mechanical property of prestressing strands. In this chapter, nineteen corroded strands are obtained through controlling stress level, corrosion time, and chloride ion concentration under artificial climate conditions. Then, the size and geometry of corrosion pits are
openaire +1 more source
Abstract During their life cycle, prestressed concrete bridges are prone to wire breaks of their tendons due to fatigue or stress corrosion cracking. However, not all structures show visible cracking on the surface, which would provide timely warning of otherwise invisible damage. Brittle failure may occur.
Noah Sträter +3 more
wiley +1 more source
Analysis of Short-Term Prestress Losses in Post-tensioned Structures Using Smart Strands
The proper estimation of prestressing force (PF) distribution is critical to ensure the safety and serviceability of prestressed concrete (PSC) structures. Although the PF distribution can be theoretically calculated based on certain predictive equations,
Sang-Hyun Kim +3 more
doaj +1 more source
Flexural behavior of precast prestressed slabs with embedded building service systems
Abstract Dry‐assembled precast concrete construction is rapidly spreading in many parts of the world due to the several advantages offered by industrialized construction. In order to speed up not only the assemblage of the structure, but also the full integrated building process, engineering systems (mechanical–electrical–plumbing) may be prefabricated
Bruno Dal Lago, Aleksei Abramov
wiley +1 more source
Abstract Several test methods have been proposed in the literature for measuring the level of residual prestress, most of them involving either semi‐ or fully destructive techniques for local measurements which could be highly sensitive to boundary conditions and execution details.
Giuseppe Zarrella +2 more
wiley +1 more source