Results 11 to 20 of about 301 (182)
A self-aware posttensioned prestressing intelligent reinforcement system with force and sensors is proposed by combining the advantages of posttensioned prestressing reinforcement technology and intelligent structure.
Guodong Li +3 more
doaj +1 more source
Flexural Behavior of Corroded High-Speed Railway Simply Supported Prestressed Concrete Box Girder
Simply supported prestressed concrete (PC) box girders have been widely adopted in high-speed railway bridges. In complex climatic environments, the corrosion of the prestressing strands always occurs and deteriorates the flexural behavior of PC box ...
Yachuan Kuang +5 more
doaj +1 more source
This paper presents the results of the tests and analysis on the coefficient of thermal expansion for the steel strand under combined low temperatures and prestressing forces.
Jian Xie, Jia-Bao Yan
doaj +1 more source
SHEAR BEHAVIOR OF STEEL BEAMS STRENGTHENING BY PRESTRESSING STRANDS
Seven simply supported steel beams were tested to explain the effect of existence of external prestressing strands on the shear behavior of steel beams.
Mohammed Mohammed Rasheed +2 more
doaj +3 more sources
Multi-Step Prestressing with Hybrid SMA Wires
Prestressing force is induced in reinforced concrete (RC) structures to improve their load-carrying capacity. Generally, the prestressing strand of an RC structure is tensioned using a hydraulic jack, which decreases its workability.
Chi-Young Jung +2 more
doaj +1 more source
Application of Large Prestress Strands in Precast/Prestressed Concrete Bridges [PDF]
The objective of this research is to investigate the advantage of using large-diameter 0.7-inch (18 mm) strands in pretention applications. Large-diameter strands are advantageous in bridge construction due to the increased girders capacity required to sustain exponential increase in vehicle numbers, sizes, and weights.
openaire +1 more source
As the main load bearing component, the steel strand has a significant impact on the safety of civil infrastructure. Real-time monitoring of steel strand stress distribution throughout the damage process is an important aspect of civil infrastructure ...
Huanyu Yang, Zhi Zhou, Jinping Ou
doaj +1 more source
Strand Corrosion in Prestressed Concrete Structures [PDF]
This is an open access book. This book focuses on the durability problems of existing prestressed concrete (PC) structures caused by strand corrosion, clarifies the mechanical behavior of corroded prestressing strands, corrosion-induced cracking, bond degradation, prestress loss and structural performance deterioration, and proposes the corresponding ...
openaire +2 more sources
Prestressing plays a pivotal role in ensuring the tightness and integrity of prestressed concrete containment in nuclear power plants. The prestress loss reduces the compressive stress in concrete resulting from the prestressing strands and increases the risk of containment leakage under severe accident conditions. Therefore, the accurate prediction of
Wu, Xingyi +3 more
openaire +2 more sources
Bond Behavior of Pretensioned Strand Embedded in Ultra-High-Performance Fiber-Reinforced Concrete
This study aimed to investigate the bond properties of prestressing strands embedded in ultra-high-performance fiber-reinforced concrete (UHPFRC). Toward this end, two types of prestressing strands with diameters of 12.7 and 15.2 mm were considered ...
Hyun-Oh Shin +2 more
doaj +1 more source