Results 191 to 200 of about 9,865,590 (355)

Non-equivalences of motivic codimension filtration quotients [PDF]

open access: yesarXiv
We prove that a motivic equivalence of objects of the form \begin{equation*} X/(X-x)\simeq X^\prime/(X^\prime-x^\prime) \end{equation*} in $\mathbf{H}^\bullet(B)$ or $\mathbf{DM}(B)$ over a scheme $B$, where $x$ and $x^\prime$ are closed points of smooth $B$-schemes $X$ and $X^\prime$, implies an isomorphism of residue fields, i.e. \[x\cong x^\prime.\]
arxiv  

Multi‐institutional study on image quality for a novel CBCT solution on O‐ring linac

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Introduction This work presents a multi‐institutional study on image quality provided by a novel cone beam computed tomography (CBCT). The main goal is to investigate the consistency of imaging performance across multiple institutions.
Luis Agulles‐Pedrós   +11 more
wiley   +1 more source

A Variational Beam Model for Failure of Cellular and Truss‐Based Architected Materials

open access: yesAdvanced Engineering Materials, EarlyView., 2023
Herein, a versatile and efficient beam modeling framework is developed to predict the nonlinear response and failure of cellular, truss‐based, and woven architected materials. It enables the exploration of their design space and the optimization of their mechanical behavior in the nonlinear regime. A variational formulation of a beam model is presented
Konstantinos Karapiperis   +3 more
wiley   +1 more source

Modelling of a double‐scattering proton therapy nozzle using the FLUKA Monte Carlo code and analysis of linear energy transfer in patients treated for prostate cancer

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The dose‐averaged linear energy transfer (LETD) in proton therapy (PT) has in pre‐clinical studies been linked to the relative biological effectiveness (RBE) of protons. Until recently, the most common PT delivery method in prostate cancer has been double‐scattered PT, with LETD only available through dedicated Monte Carlo (MC ...
Rasmus Klitgaard   +7 more
wiley   +1 more source

A review of artificial intelligence in brachytherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Artificial intelligence (AI) has the potential to revolutionize brachytherapy's clinical workflow. This review comprehensively examines the application of AI, focusing on machine learning and deep learning, in various aspects of brachytherapy.
Jingchu Chen   +4 more
wiley   +1 more source

Feasibility study of skin dosimetry with TLD sheets for measuring the effect of 3D printed bolus in radiotherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract The thermoluminescence dosimeter (TLD) sheet is a measurement device coated with manganese‐doped LiB3O5 in sheet form. The sheet is 0.2‐mm thick and flexible. Hence, it can fit and be installed on irregular surfaces. The current study aimed to evaluate the feasibility of measuring patient surface doses during radiation therapy using TLD sheets.
Yuya Miyasaka   +8 more
wiley   +1 more source

Evaluating the use of diagnostic CT with flattening filter free beams for palliative radiotherapy: Dosimetric impact of scanner calibration variability

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Palliative radiotherapy comprises a significant portion of the radiation treatment workload. Volumetric‐modulated arc therapy (VMAT) improves dose conformity and, in conjunction with flattening filter free (FFF) delivery, can decrease treatment times, both of which are desirable in a population with a high probability of retreatment ...
Madeleine L. Van de Kleut   +2 more
wiley   +1 more source

Evaluation of the effect of metal stents on dose perturbation in the carbon beam irradiation field

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Propose Carbon ion therapy is indicated for cases in which stents have been inserted, such as bile ducts, but the effect of metal stents on carbon ion therapy is unclear. In this study, the dose perturbation of carbon ion therapy caused by metallic bile duct stents was evaluated by dosimetry. Materials and methods Five different types of metal
Yuya Miyasaka   +8 more
wiley   +1 more source

Home - About - Disclaimer - Privacy