Results 131 to 140 of about 585,275 (266)

Automated FRAP microscopy for high‐throughput analysis of protein dynamics in chromatin organization and transcription

open access: yesFEBS Open Bio, EarlyView.
RoboMic is an automated confocal microscopy pipeline for high‐throughput functional imaging in living cells. Demonstrated with fluorescence recovery after photobleaching (FRAP), it integrates AI‐driven nuclear segmentation, ROI selection, bleaching, and analysis.
Selçuk Yavuz   +6 more
wiley   +1 more source

Raman‐based label‐free microscopic analysis of the pancreas in living zebrafish larvae

open access: yesFEBS Open Bio, EarlyView.
Forward stimulated Raman scattering (F‐SRS) and epi coherent anti‐Stokes Raman scattering (E‐CARS) allow label‐free discrimination of distinct subcellular structures in the pancreas of living zebrafish larvae. Given the straightforward applicability, we anticipate broad implementation of Raman microscopy in other organs and across various biomedical ...
Noura Faraj   +3 more
wiley   +1 more source

Single‐molecule DNA flow‐stretch assays for high‐throughput DNA–protein interaction studies

open access: yesFEBS Open Bio, EarlyView.
We describe an optimised single‐molecule DNA flow‐stretch assay that visualises DNA–protein interactions in real time. Linear DNA fragments are tethered to a surface and stretched by buffer flow for fluorescence imaging. Using λ and φX174 DNA, this protocol enhances reproducibility and accessibility, providing a versatile approach for studying diverse ...
Ayush Kumar Ganguli   +8 more
wiley   +1 more source

Myelin damage in radiologically isolated syndrome is associated with decreased processing speed. [PDF]

open access: yesMult Scler J Exp Transl Clin
Kalau O   +17 more
europepmc   +1 more source

Optimizing photoactivation of PA‐mCherry for optical pooled CRISPR screens

open access: yesFEBS Open Bio, EarlyView.
Photoactivatable PA‐mCherry finds widespread use to optically tag individual cells. However, confocal 405 nm UV laser‐scanning (normal scan) is much less efficient than widefield UV illumination, limiting the use of PA‐mCherry on confocal instruments. We remedy this limitation by reporting that rapid and repeated confocal scanning with a low‐intensity,
Sravasti Mukherjee   +3 more
wiley   +1 more source

Cognitive Processing Speed Assessment Combined With Gait Performance Improves Prediction of Shunt Surgery Responsiveness in Idiopathic Normal Pressure Hydrocephalus. [PDF]

open access: yesCNS Neurosci Ther
Geng Z   +15 more
europepmc   +1 more source

RoundMi: A quantitative method to analyze mitochondrial morphology in mitotic cells

open access: yesFEBS Open Bio, EarlyView.
RoundMi is a workflow for rapid analysis of mitochondrial morphology in mitotic cells. By combining adaptive preprocessing with automated segmentation and quantification, it enables accurate measurements from single focal plane images, reducing acquisition time and computational demands while remaining compatible with high‐throughput fixed and live ...
Elmira Parvindokht Bararpour   +2 more
wiley   +1 more source

The Victorians were still faster than us. Commentary: Factors influencing the latency of simple reaction time

open access: yesFrontiers in Human Neuroscience, 2015
Michael Anthony Woodley of Menie   +2 more
doaj   +1 more source