Results 51 to 60 of about 27,465 (240)
Introduction: Automated target volumes adaptation could be useful in H&N replanning, but its dosimetric impact has not been analyzed. Primary aim of this investigation is dose coverage assessment in fully automated and edited PTV adaptation settings ...
Gian Carlo Mattiucci +11 more
doaj +1 more source
This study evaluated four stereotactic radiosurgery planning approaches for posterior choroidal melanoma (CM). Analysis of thirteen CM cases resulted in a clinically meaningful reduction in dose to the brain for Brainlab Elements modulated arcs (BE) and Varian Eclipse HyperArc modulated arcs (HA) compared to Brainlab iPlan dynamic conformal arc therapy
Robert Nigro +5 more
wiley +1 more source
Renal reversed rotation is a congenital abnormality due to anomalous kidney rotation around its long axis, resulting in faced laterally renal hilum; this condition is associated with several vascular variants.
Francesca Di Giuliano, MD +6 more
doaj +1 more source
Background In stereotactic radiotherapy, dose is prescribed to an isodose surrounding the planning target volume (PTV). However, the desired dose inhomogeneity inside the PTV leaves the specific dose distribution to the gross tumor volume (GTV ...
Christine Kornhuber +6 more
doaj +1 more source
This study compares two techniques for creating lead shielding masks to replace the current process for superficial/orthovoltage facial radiotherapy: Plaster Cast Positive Mould (PCPM), CT Scanned 3D Print (CT3DP), and Optical Scan 3D Print (OS3DP). CT3DP was found to be more accurate and preferred over OS3DP.
Rory Hartley +6 more
wiley +1 more source
This review highlights the role of functional imaging in sparing cognitive brain regions during glioma radiotherapy. It shows promising dose reduction without compromising target coverage, but evidence remains limited, requiring standardisation and prospective validation.
Li Wen Yeo, John T. Ryan
wiley +1 more source
Prone Breast Radiotherapy on the MR‐Linac: A Technical Note on Skin‐Couch Contact Dose Effects
This retrospective planning study evaluated the dosimetric effects of skin‐couch contact during prone APBI on a 1.5 T MR‐Linac by comparing treatment plans calculated with and without a magnetic field. While the presence of the magnetic field increased overall superficial skin dose, it consistently reduced dose at the skin‐couch contact region ...
Kerryn Brown +7 more
wiley +1 more source
Spontaneous Ureteral Rupture Diagnosis and Treatment
Rupture of the urinary collecting system associated with perinephric or retroperitoneal extravasation of the urine is an unusual condition and it is commonly associated with renal obstructing disease.
E. Pampana +5 more
doaj +1 more source
Background Although circular collimator arcs (CCA) and dynamic conformal arcs (DCA) are commonly used linear accelerator-based treatment planning techniques for intracranial stereotactic radiosurgery (SRS) of a small single lesion, these two techniques ...
Yongsook C. Lee, Yongbok Kim
doaj +1 more source
This analysis included quantification of intrafraction motion in pancreas stereotactic ablative radiotherapy treated on the MR‐Linac, leading to the development of adjusted (PTV) margins. Intrafraction motion indicated an average target displacement of 1–3 mm, resulting in an adjusted PTV margin of 2 mm in the right–left and superior–inferior ...
Ashleigh Fasala +6 more
wiley +1 more source