Results 101 to 110 of about 162,660 (354)

Preprocedure Application of Machine Learning and Mechanistic Simulations Predicts Likelihood of Paroxysmal Atrial Fibrillation Recurrence Following Pulmonary Vein Isolation

open access: yesCirculation: Arrhythmia and Electrophysiology, 2020
Supplemental Digital Content is available in the text. Background: Pulmonary vein isolation (PVI) is an effective treatment strategy for patients with atrial fibrillation (AF), but many experience AF recurrence and require repeat ablation procedures. The
J. Shade   +8 more
semanticscholar   +1 more source

Smart Catheters for Diagnosis, Monitoring, and Therapy

open access: yesAdvanced Healthcare Materials, EarlyView.
This study presents a comprehensive review of smart catheters, an emerging class of medical devices that integrate embedded sensors, robotics, and communication systems, offering increased functionality and complexity to enable real‐time health monitoring, diagnostics, and treatment. Abstract This review explores smart catheters as an emerging class of
Azra Yaprak Tarman   +12 more
wiley   +1 more source

Usefulness of filtered unipolar electrogram morphology for evaluating transmurality of ablated lesions during pulmonary vein isolation

open access: yesJournal of Arrhythmia, 2016
Background: Although alteration of the amplitude and morphology of bipolar electrograms is used widely as a guide of the ablation effect, there is little information concerning unipolar electrograms.
Rikitake Kogawa, MD   +12 more
doaj   +1 more source

Long-Term Results of Pulmonary Vein Isolation Plus Modified Posterior Wall Debulking Utilizing High-Power Short-Duration Strategy: An All-Comers Study in Real World

open access: yesAnatolian Journal of Cardiology, 2022
Background: High-power short-duration radiofrequency ablation has improved lesion durability in pulmonary vein isolation. In this study, we investigate long-term clinical out-comes of high-power short-duration pulmonary vein isolation and posterior wall ...
Basar Candemir   +6 more
doaj   +1 more source

Advanced ablation strategies for management of post-surgical atrial arrhythmias. [PDF]

open access: yes, 2013
Post-surgical arrhythmias include a wide range of arrhythmias occurring late after cardiac surgery and represent a complex substrate for catheter ablation either because of extended scar and remodeling or because of limited access to the area of interest.
Babu-Narayan, SV   +3 more
core   +1 more source

A Versatile Engineering Platform for the Fabrication of Prosthetic Venous Valves Using Electrospinning

open access: yesAdvanced Healthcare Materials, EarlyView.
Percutaneous prosthetic venous valves are fabricated by embedding stents in an electrospun matrix that extends luminally to form leaflets. The design shields leaflets from hyperplastic cells, isolates struts from blood contact, and avoids discrete anchoring points.
Dario Arcuti   +6 more
wiley   +1 more source

Successful intraprocedural anticoagulation with bivalirudin during pulmonary vein isolation in a patient with known heparin-induced thrombocytopenia type II

open access: yesJournal of Arrhythmia, 2016
We report the case of a 56-year-old female who presented with symptomatic paroxysmal atrial fibrillation. Anamnestic heparin-induced thrombocytopenia (HIT) type II was suspected, and a rapid diagnostic test showed antibodies against platelet factor 4 ...
Barbara Bellmann, MD   +2 more
doaj   +1 more source

Incidence and predictors of premature ventricular complexes following catheter ablation for atrial fibrillation [PDF]

open access: yes, 2017
BACKGROUND: Atrial fibrillation (AF) is the most common cardiac arrhythmia, and previous studies have focused on the epidemiology, mechanisms and risk factors for this global disease (Ryder and Benjamin 1999). Various studies have examined the mechanism,
Harvey, Joshua
core  

Pulmonary Vein Isolation With Very High Power, Short Duration, Temperature-Controlled Lesions: The QDOT-FAST Trial.

open access: yesJACC Clinical Electrophysiology, 2019
OBJECTIVES This study sought to evaluate the safety and short-term performance of a novel catheter for very high power-short duration (vHPSD) ablation in the treatment of paroxysmal atrial fibrillation.
V. Reddy   +10 more
semanticscholar   +1 more source

Non‐Invasive Multidimensional Capacitive Sensing for In Vivo Traumatic Brain Injury Monitoring

open access: yesAdvanced Materials Technologies, EarlyView.
Single‐electrode, multidimensional capacitive sensors noninvasively assess cerebral autoregulation and compliance for traumatic brain injury monitoring. ABSTRACT Traumatic brain injury (TBI) is a major cause of death and disability, but invasive intracranial pressure (ICP) monitoring is risky, and current non‐invasive methods lack the resolution and ...
Shawn Kim   +8 more
wiley   +1 more source

Home - About - Disclaimer - Privacy