Push–out Test of Timber Concrete Composite Construction [PDF]
In this study, push – out test specimen is proposed to explore the behavior of shear connectors in timber–concrete composite beams. Since there are no standard shapes and dimensions for determining the strength of connectors, push–out specimens such as ...
Ihab Saleh +2 more
doaj +4 more sources
Bond strength of different endodontic sealers to dentin: push-out test [PDF]
OBJECTIVE: The aim of this in vitro study was to evaluate the bond strength of different root canal sealers to dentin. MATERIAL AND METHODS: Forty extracted single-rooted human teeth were examined and the coronal and middle thirds of the canals were ...
João Vicente Baroni Barbizam +4 more
doaj +8 more sources
Material characteristics of push-out tests
Abstract Two types of push-out tests were carried out at the Centre of Research and Innovation in Construction, the Technical University of Košice - one at a composite based on steel continuous shear connector and the second one at the same connector, however made of glass-laminate material.
Patrícia Vaňová +2 more
openalex +2 more sources
A finite element analysis of the push‐out test: Influence of test conditions [PDF]
AbstractThe commonly used method for quantitative evaluation of the strength of a bone‐implant interface is the push‐out test. In order to give an impulse to standardization and to gain more insight in the biomechanics of the push‐out test, a finite element analysis of this test was performed.
Wouter J.A. Dhert +6 more
openalex +4 more sources
Comparison of different fiber post systems using push-out bond strength test
Background and Objective: Nowadays, the use of fiber post in weak teeth that had root canal treatment has gained acceptance worldwide. New materials and shapes of fiber posts were introduced.
Hani M. Mouafaq, Shakhawan K. Kadir
doaj +2 more sources
Testing and Numerical Modelling of Steel-Concrete-Steel with Stud Bolts Connectors Subject to Push-Out Loading [PDF]
Steel-concrete-steel (SCS) sandwich panels are composed of two steel plates with low thicknesses and high densities and strengths and one thick layer between both plates with low strength and density known as core that is composed of concrete.
Mohammad Golmohammadi +1 more
doaj +2 more sources
Influence of micro‐structure on fibre push‐out tests [PDF]
AbstractIn fibre reinforced materials, the interface toughness has a significant influence on strength and damage resistance. Especially in discontinuous fibre reinforced composites, where high densities of fibre ends are apparent, it has been shown that additives which improve the interfacial toughness can increase the effective strength of the ...
Barthel Brylka +3 more
openalex +4 more sources
Numerical investigation of internal force transfer mechanism in push-out tests
International audienceThe case of a push-out test specimen made of prefabricated slabs connected by means of grouped headed studs is investigated in this study.
Samy Guezouli +2 more
openalex +4 more sources
Mechanical testing of titanium/aluminium–silicon interfaces by push-out [PDF]
Mechanical properties of Ti/Al–7Si assemblies produced by insert moulding were studied with a classical push-out test and a variant that is the circular-bending test. Special care has been taken for controlling both the reactivity at the Ti/Al–7Si interface and the metallurgical health of the Al–7Si matrix.
Olivier Dezellus +5 more
openalex +3 more sources
An ex vivo comparison of bond strength measured by the push-out test between AH Plus and Endosequence BC sealer Hiflow [PDF]
Thayane da Costa Pinheiro +11 more
openalex +2 more sources

