Results 1 to 10 of about 749,971 (303)
Influence of Brake Device Push-out Stiffness on Vibration Performance of Rail Transit Vehicle
Objective As a braking mode,electromechanical brake adopts the motor controlled screw rod drive to implement the pushing action, making the brake shoe to contact with the wheel and complete the transmission of brake force and friction brake.
LIU Yinhu +5 more
doaj +2 more sources
Formulating a design for a screw-type shear connector in a compo-site section
Screws-type shear connectors have been most used in Colombia during the last decade; however, an expression for their design in composite sections has only recently been presented (NSR10, paragraph F.2.9.8.2.2).
Maritzabel Molina Herrera +1 more
doaj
Considerations about the use of the “push‐out” test in Endodontic research [PDF]
Moinzadeh, A.T. +2 more
openaire +5 more sources
Push-out failure is easy to happen in stud shear connector with small length-diameter ratio of stud. At present, the bearing capacity of push-out failure mode is usually determined by test.
Qianhui PU +5 more
doaj
Background: To provide a continuous seal of the root canal, root-filling material should bond to the root canal dentin, ensuring the integrity of both the root-filling material and dentin remains in a static and functional state.
Fatemeh Mokhtari +2 more
doaj +1 more source
Aim: The study’s objective is to assess the bond strengths of four different endodontic sealers to root dentin using a push-out test technique. Material and Method: Sixty single-rooted teeth were selected and decoronated.
Joyeta Ghosh +5 more
doaj +1 more source
Analytical Model for Load⁻Slip Relationship of Perfobond Shear Connector Based on Push-Out Test. [PDF]
Zheng S, Zhao C, Liu Y.
europepmc +1 more source
Aim: The study aimed to assess the postobturation push-out bond strength of noneugenol-based sealers among different activation groups. Methods: One hundred sixteen single-rooted extracted mandibular premolar teeth were obtained. They were split into six
Aabha Gautam Dave +2 more
doaj +1 more source
Effect of Previous Fire on Load-Slip Relationship at a Modified Push-Out Test (Experimental Study)
In this paper, the effect of previous heating on load-slip relationship in modified push-out test is studied. Specimens of concrete slab with connectors (connector embedded in the concrete slab) were put in an oven of high heating for at least one hour ...
Mukhallad A. Al-Sa’ady
doaj
An in vitro Comparison of Bond Strength of Different Sealers/Obturation Systems to Root Dentin Using the Push-Out Test at 2 Weeks and 3 Months after Obturation. [PDF]
Yap WY +4 more
europepmc +1 more source

