Results 241 to 250 of about 15,633,684 (298)
Total femoral replacement for severe femoral bone loss in non-oncologic patients: high complication rates but acceptable functional outcomes. [PDF]
Mielgo IM +3 more
europepmc +1 more source
Design of a fixture for precise perpendicular cuts in bone-implant sample preparation. [PDF]
Genchev M +6 more
europepmc +1 more source
Effect of Root Canal Drying Methods on Bioceramic Sealer Bond Strength. [PDF]
Ozden I +3 more
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Micromechanical analysis of the fiber push-out and re-push test
Composites Science and Technology, 1998Abstract The objective of this work is to employ the variational model of a concentric cylinder to model accurately the fiber push-out (and re-push) test used for evaluation of interfacial properties. In this paper, the detailed stress distributions and load/displacement solutions obtained by considering a variety of interface boundary conditions ...
N J Pagano, G P Tandon
exaly +2 more sources
Analyses of the fiber push-out test
International Journal of Solids and Structures, 1993Abstract A two-dimensional model of the fiber push-out test is considered. Two distinct methods of analysis are independently employed in solving the problem, and their accuracy is indicated by the virtual coincidence of the results. Interfacial debonding is assumed to be characterized by a cohesive zone model, and subsequent slippage obeys a Coulomb
A. Dollar +3 more
openaire +1 more source
Journal of Petroleum Science and Engineering, 2019
Abstract Bonding between cement and steel is currently believed to be of key importance in well integrity since it prevents the development of microannulus. Push-out test is often used to quantify the bonding strength between cement and steel in laboratory.
Alexandre Lavrov +2 more
openaire +1 more source
Abstract Bonding between cement and steel is currently believed to be of key importance in well integrity since it prevents the development of microannulus. Push-out test is often used to quantify the bonding strength between cement and steel in laboratory.
Alexandre Lavrov +2 more
openaire +1 more source
FE validation of push‐out tests
Steel Construction, 2017AbstractThe prefabrication of concrete slabs reduces construction time and the total life cycle cost of composite steel‐concrete buildings and bridge decks. Using bolts as shear connectors embedded in prefabricated concrete slabs enables reuse and easy replacement of slabs as structural members suitable for a circular economy construction concept.
Marko Pavlović, Milan Veljković
openaire +1 more source
Simulation of fiber pushing-out test
Journal of Wuhan University of Technology-Mater. Sci. Ed., 2009The stress distribution on the failure progress of fiber pushed-out test was studied. A numerical program, developed by meso-damage mechanics, was adopted to simulate the whole failure process of interface debonding and fiber pushing out. From the simulation, it can be concluded that, the interfacial stress on load side and support side is larger than ...
Yafang Zhang, Hao Liu, Lei Qi
openaire +1 more source
Partial-interaction analysis with push-out tests
Journal of Constructional Steel Research, 2005Abstract This paper deals with an experimental and analytical study to simulate partial-interaction behavior by using push-out results for steel–concrete composite members. In order to analyze the interface behavior of steel–concrete by the degree of interaction, a total of 9 push-out test specimens were tested.
Youn-Ju Jeong +2 more
openaire +1 more source
Push-Out Test on Shear Connectors Embedded in UHPC
Applied Mechanics and Materials, 2013The various push-out tests have been performed to investigate the load carrying capacity and ultimate behavior of headed studs in UHPC (Ultra High Performance Concrete), which has high compressive and tensile strength as well as high durability compared to ordinary concrete.
Jee Sang Kim +4 more
openaire +1 more source