Results 261 to 270 of about 15,633,684 (298)
Some of the next articles are maybe not open access.
Behaviour of headed studs in composite beams: push-out tests
Canadian Journal of Civil Engineering, 1988This paper briefly summarizes the results of tests conducted on 18 full-size push-out specimens and 4 pull-out specimens. The objective of the project was to study the behaviour of headed studs in composite beams with ribbed metal decks perpendicular and parallel to the steel beam.
B. S. Jayas, M. U. Hosain
openaire +1 more source
Pull-Out and Push-Out Tests for Rubber-to Metal Adhesion
Rubber Chemistry and Technology, 1989Abstract A study has been carried out of adhesive failure forces for a steel rod embedded in and bonded to a rubber block. Emphasis has been placed on comparing tension (pull-out) and compression (push-out) forces. A fractional contribution to the pull-out force appeared to be significant for rods having a diameter greater than about 0.5 mm in ...
A. N. Gent, S. Y. Kaang
openaire +1 more source
Mechanic Model of Push-Out Test of Over-Thick CFST
Applied Mechanics and Materials, 2014Analyze mechanical behavior of over-thick concrete filled steel tube ( over-thick CFST ) subjected to axial compression and revealed adhesive slip law of steel tube/concrete. Axial symmetry elasticity modeling of the concrete column which is constrained by over-thick steel tube and pushed out under axial compressive load is set up.
Jin He Gao +2 more
openaire +1 more source
Cohesive Zone Approach to Interpreting the Fiber Push‐Out Test
Journal of the American Ceramic Society, 1993A means of inferring interface parameters from the fiber push‐out test is proposed. The significant feature of the approach is the use of a cohesive zone model to capture fiber‐matrix interfacial debonding. The approach is used to interpret push‐out data obtained from silicon carbide/silicon nitride composites.
Anna Dollar, Paul S. Steif
openaire +1 more source
Push-out Tests on Headed Studs in High-Strength Concrete
SP-228: 7th Intl Symposium on the Utilization of High-Strength/High-Performance Concrete, 2005Composite structures made of structural steel and concrete maximize the advantages of the two components, especially, when using high strength materials. The interaction of the two materials is guaranteed by shear connectors. Experimental and numerical investigations at the Institute of Structural Concrete, RWTH Aachen University indicate that headed ...
openaire +1 more source
Measurement of Interface Propertes from Fiber Push-Out Tests
2008The Kerans and Parthasarathy (1991) analysis method is presently applied to flat-probe push-out test data obtained from SiC-reinforced glass matrix composites. Upon removal of the system compliance from the data prior to analysis, the true behavior of the composite was clearly in evidence; several qualitative characterizations accordingly became ...
P. D. Jero +2 more
openaire +1 more source
Methodological considerations on push‐out tests in Endodontics
International Endodontic Journal, 2015G, De-Deus, E, Souza, M, Versiani
openaire +2 more sources
Singularity of Interface Stresses in Fibre Push-Out Test
Key Engineering Materials, 2002Joo Hyuk Park, Ying Dai, Jang Kyo Kim
openaire +1 more source
The influence of push and pull factors at Korean national parks
Tourism Management, 2003David B Klenosky +2 more
exaly

