Results 91 to 100 of about 196 (119)
Experimental technique to measure thoron generation rate of building material samples using RAD7 detector [PDF]
Thoron ( 220 Rn) is the second most abundant radon isotope in our living environment. In some dwellings it is present in significant amount which calls for its identification and remediation. Indoor thoron originates mainly from building materials. In this work we have developed and tested an experimental technique to measure thoron generation rate in ...
Csaba SZABÓ, I Csige
exaly +3 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
DNA Repair, 2004
Nucleotide excision repair (NER) in eukaryotes removes DNA base damage as an oligonucleotide in a complex series of reactions. The nature of the dual incision reactions on either side of the damaged base has been extensively investigated. However, the precise mechanism of cleavage of the phosphodiester backbone of the DNA by the NER endonucleases and ...
Tom Owen-Hughes +2 more
exaly +3 more sources
Nucleotide excision repair (NER) in eukaryotes removes DNA base damage as an oligonucleotide in a complex series of reactions. The nature of the dual incision reactions on either side of the damaged base has been extensively investigated. However, the precise mechanism of cleavage of the phosphodiester backbone of the DNA by the NER endonucleases and ...
Tom Owen-Hughes +2 more
exaly +3 more sources
Determination of radon concentration in water using RAD7 with RAD H2O accessories
AIP Conference Proceedings, 2015In the last decade, the radon issue has become one of the major problems of radiation protection. Radon exposure occurs when using water for showering, washing dishes, cooking and drinking water. RAD7 and Rad H20 accessories were used in order to measure radon concentration in water sample.
M. F. I. Malik +2 more
openaire +1 more source
Molecular Genetics and Genomics, 1982
Excision of pyrimidine dimers and interstrand DNA crosslinks was examined in the deletion mutants rad7-delta 1, rad23-delta 1, and rad7-delta 1 rad23-delta 1. These mutants remove pyrimidine dimers and crosslinks much less efficiently than the RAD+ strains; only 30-60% of pyrimidine dimers and 25-40% of crosslinks are removed even after prolonged ...
Satya Prakash +2 more
exaly +3 more sources
Excision of pyrimidine dimers and interstrand DNA crosslinks was examined in the deletion mutants rad7-delta 1, rad23-delta 1, and rad7-delta 1 rad23-delta 1. These mutants remove pyrimidine dimers and crosslinks much less efficiently than the RAD+ strains; only 30-60% of pyrimidine dimers and 25-40% of crosslinks are removed even after prolonged ...
Satya Prakash +2 more
exaly +3 more sources
Radiation Protection Dosimetry, 2013
Radon gas is a significant health threat linked to thousands of preventable deaths each year. In this paper, radon activity concentration is measured in 260 groundwater samples collected from 65 villages in the Bathinda district of Punjab State, India, using Rad7, an electronic radon detector (Durridge Co., USA). The radon concentration varies from 0.9
Vikas, Duggal, Rohit, Mehra, Asha, Rani
openaire +2 more sources
Radon gas is a significant health threat linked to thousands of preventable deaths each year. In this paper, radon activity concentration is measured in 260 groundwater samples collected from 65 villages in the Bathinda district of Punjab State, India, using Rad7, an electronic radon detector (Durridge Co., USA). The radon concentration varies from 0.9
Vikas, Duggal, Rohit, Mehra, Asha, Rani
openaire +2 more sources
Applied Radiation and Isotopes, 2015
A procedure for the determination of (222)Rn in environmental water samples using liquid scintillation counting (LSC) was applied and optimized. A minimum detectable activity of 0.029Bql(-1) in a 20ml glass vial (10ml water sample mixed with 10ml of liquid scintillation cocktail) has been achieved during 300min of measurement time.
Ivana Stojković +2 more
exaly +3 more sources
A procedure for the determination of (222)Rn in environmental water samples using liquid scintillation counting (LSC) was applied and optimized. A minimum detectable activity of 0.029Bql(-1) in a 20ml glass vial (10ml water sample mixed with 10ml of liquid scintillation cocktail) has been achieved during 300min of measurement time.
Ivana Stojković +2 more
exaly +3 more sources
NeuroQuantology, 2022
In this study, the average radon gas concentration for different types of water was measured in AL-Najaf refinery by using RAD7 monitor manufactured by DURRIDGE company, USA, there are two sources of water inside the refinery, river water, and well water, at RO unit inside the refinary, they use 50% of well water (W1) and 50% of river water (W7), as ...
Mokhalad A. Mohammed, Rawaa M. Obaid
openaire +1 more source
In this study, the average radon gas concentration for different types of water was measured in AL-Najaf refinery by using RAD7 monitor manufactured by DURRIDGE company, USA, there are two sources of water inside the refinery, river water, and well water, at RO unit inside the refinary, they use 50% of well water (W1) and 50% of river water (W7), as ...
Mokhalad A. Mohammed, Rawaa M. Obaid
openaire +1 more source
Molecular and General Genetics MGG, 1979
The ability to remove ultraviolet (UV)-induced pyrimidine dimers from the nuclear DNA of yeast was examined in two radiation-sensitive (rad) mutants and one methyl methanesulfonate-sensitive (mms) mutant of the yeast Saccharomyces cerevisiae. The susceptibility of DNA from irradiated cells to nicking by an endonuclease activity prepared from crude ...
L, Prakash, S, Prakash
openaire +2 more sources
The ability to remove ultraviolet (UV)-induced pyrimidine dimers from the nuclear DNA of yeast was examined in two radiation-sensitive (rad) mutants and one methyl methanesulfonate-sensitive (mms) mutant of the yeast Saccharomyces cerevisiae. The susceptibility of DNA from irradiated cells to nicking by an endonuclease activity prepared from crude ...
L, Prakash, S, Prakash
openaire +2 more sources
Zastosowanie przenośnego detektora RAD7 do badania koncentracji radonu w wodzie
Nafta-GazW artykule przedstawiono metodykę badania koncentracji radonu w próbkach wody z zastosowaniem aparatury RAD7. Aparatura ta została dodatkowo wyposażona w systemem Big Bottle, przeznaczony do określania niskich stężeń radonu w wodzie. W ramach pracy przeprowadzono szereg badań terenowych i laboratoryjnych, a najważniejsze wyniki zestawiono i opisano w ...
Rafał Skupio, Kamil Hebda
openaire +1 more source
Radiation Protection Dosimetry, 2012
Radon monitoring has been increasingly conducted worldwide because of the hazardous effects of radon on the health of human beings. In the present research, groundwater samples were taken from hand pumps at different areas of the districts of SriGanganagar, Hanumangarh, Sikar and Churu in northern Rajasthan. RAD7, an electronic radon detector (Durridge
Asha, Rani, Rohit, Mehra, Vikas, Duggal
openaire +2 more sources
Radon monitoring has been increasingly conducted worldwide because of the hazardous effects of radon on the health of human beings. In the present research, groundwater samples were taken from hand pumps at different areas of the districts of SriGanganagar, Hanumangarh, Sikar and Churu in northern Rajasthan. RAD7, an electronic radon detector (Durridge
Asha, Rani, Rohit, Mehra, Vikas, Duggal
openaire +2 more sources