Results 171 to 180 of about 1,000 (198)
Some of the next articles are maybe not open access.

High radon levels and adverse environmental conditions in using RAD7

Radiation Protection Dosimetry, 2023
Abstract Good response was observed in simultaneously using six RAD7 detectors at high radon concentrations, temperatures and relative humidity conditions. RAD7 detectors were tested in laboratory using radon chambers from 13 up to 59.8 kBq m−3, statistical analysis allows to distinct between counting errors and radon variation.
Arturo, Lopez   +2 more
openaire   +2 more sources

RAD7 homologues contribute to Arabidopsis UV tolerance

Plant Science, 2018
Frequent exposure of plants to solar ultraviolet radiation (UV) results in damaged DNA. One mechanism of DNA repair is the light independent pathway Global Genomic Nucleotide Excision Repair (GG-NER), which repairs UV damaged DNA throughout the genome.
Triparna Lahari   +3 more
openaire   +2 more sources

Transposition of the gene cluster CYC1-OSM1-RAD7 in yeast

Journal of Molecular Biology, 1981
Abstract A mutant of the yeast Saccharomyces cerevisiae contains an increased amount of iso-1-cytochrome c because two copies of a segment, denoted COR, were transposed to a new position on chromosome VII, while the original COR region was retained at the normal position on chromosome X; this COR segment encompasses the CYC1, OSM1 and RAD7 loci which
J I, Stiles   +4 more
openaire   +2 more sources

The Effect of RAD7 Gene’s Null Mutation on Single-Cell Aging

Microbial Bioactive, 2022
Background: Although different theories and hypotheses were postulated for aging, molecular mechanisms of its regulations are still vastly unknown. In time, a post-mitotic cell ages with the aggregation of mutations within its genome and reach senescence. The DNA repair system that protects its genome also malfunctions with time.
openaire   +1 more source

Determination of radon concentration in water using RAD7 with RAD H2O accessories

AIP Conference Proceedings, 2015
In the last decade, the radon issue has become one of the major problems of radiation protection. Radon exposure occurs when using water for showering, washing dishes, cooking and drinking water. RAD7 and Rad H20 accessories were used in order to measure radon concentration in water sample.
M. F. I. Malik   +2 more
openaire   +1 more source

Determination of 222RN level in groundwater using a Rad7 detector in the Bathinda district of Punjab, India

Radiation Protection Dosimetry, 2013
Radon gas is a significant health threat linked to thousands of preventable deaths each year. In this paper, radon activity concentration is measured in 260 groundwater samples collected from 65 villages in the Bathinda district of Punjab State, India, using Rad7, an electronic radon detector (Durridge Co., USA). The radon concentration varies from 0.9
Vikas, Duggal, Rohit, Mehra, Asha, Rani
openaire   +2 more sources

Measurement of Radon Gas Concentrations for different Types of Water in AL-Najaf Refinery by Using RAD7 Monitor

NeuroQuantology, 2022
In this study, the average radon gas concentration for different types of water was measured in AL-Najaf refinery by using RAD7 monitor manufactured by DURRIDGE company, USA, there are two sources of water inside the refinery, river water, and well water, at RO unit inside the refinary, they use 50% of well water (W1) and 50% of river water (W7), as ...
Mokhalad A. Mohammed, Rawaa M. Obaid
openaire   +1 more source

Three additional genes involved in pyrimidine dimer removal in Saccharomyces cerevisiae: RAD7, RAD14 and MMS19

Molecular and General Genetics MGG, 1979
The ability to remove ultraviolet (UV)-induced pyrimidine dimers from the nuclear DNA of yeast was examined in two radiation-sensitive (rad) mutants and one methyl methanesulfonate-sensitive (mms) mutant of the yeast Saccharomyces cerevisiae. The susceptibility of DNA from irradiated cells to nicking by an endonuclease activity prepared from crude ...
L, Prakash, S, Prakash
openaire   +2 more sources

Zastosowanie przenośnego detektora RAD7 do badania koncentracji radonu w wodzie

Nafta-Gaz
W artykule przedstawiono metodykę badania koncentracji radonu w próbkach wody z zastosowaniem aparatury RAD7. Aparatura ta została dodatkowo wyposażona w systemem Big Bottle, przeznaczony do określania niskich stężeń radonu w wodzie. W ramach pracy przeprowadzono szereg badań terenowych i laboratoryjnych, a najważniejsze wyniki zestawiono i opisano w ...
Rafał Skupio, Kamil Hebda
openaire   +1 more source

Home - About - Disclaimer - Privacy