Results 81 to 90 of about 32,896 (264)
Dosimetric Considerations in Radioimmunotherapy and Systemic Radionuclide Therapies: A Review
Radiopharmaceutical therapy, once touted as the "magic bullet" in radiation oncology, is increasingly being used in the treatment of a variety of malignancies; albeit in later disease stages. With ever-increasing public and medical awareness of radiation
Kelvin Loke +4 more
doaj +1 more source
This study established that patient's lateral width measurements made from scanned projection radiograph (SPR) is an overestimate compared to those measured from tomographic slices by about 10%. Size‐specific dose estimates (SSDE) calculated using lateral width measured from SPR correlates well with SSDE calculated using water equivalent diameter of ...
Ajit Brindhaban
wiley +1 more source
The image reconstruction influence in relative measurement in SPECT / PET / CT animal
The objective of this study was to evaluate spatial resolution and the influence of different reconstruction methods in a FLEX Triumph ™ Pre-Clinical Imaging System images applied to mice C57BL6 dosimetry in a new radiopharmaceuticals development for ...
Sarah Soriano +3 more
doaj +1 more source
This analysis included quantification of intrafraction motion in pancreas stereotactic ablative radiotherapy treated on the MR‐Linac, leading to the development of adjusted (PTV) margins. Intrafraction motion indicated an average target displacement of 1–3 mm, resulting in an adjusted PTV margin of 2 mm in the right–left and superior–inferior ...
Ashleigh Fasala +6 more
wiley +1 more source
Sensitivity of the IRD whole-body counter for in vivo measurements in the case of accidental intakes
Intakes of radionuclides by humans may occur in the fuel cycle, nuclear medicine, biological research and in TENORM industries and in case of accidents involving workers and the general public.
Bernardo Maranhão Dantas +2 more
doaj +1 more source
Molecular theranostics: principles, challenges and controversies
Molecular theranostics offers a powerful tool to drive precision medicine in nuclear oncology. While theranostics is not a new principle in nuclear medicine, recent advances in instrumentation and radiopharmacy have driven a reinvigoration and a broader suite of applications.
Geoffrey Currie
wiley +1 more source
In 2020, our institution transitioned to the Eclipse™ treatment planning system and to Truebeam® linear accelerators with 6 MV and 10 MV energies. The linear accelerators were installed in smaller bunkers that could not accommodate 400 cm FAD. A multidisciplinary team within the institution was created to evaluate existing total body irradiation ...
Gabriella La Macchia +5 more
wiley +1 more source
ABSTRACT This study aimed to evaluate the predictive value of the estimated dose of radiation to immune cells (EDRIC) in patients with esophageal cancer receiving radical radiotherapy. We retrospectively reviewed the data of patients with esophageal cancer who underwent definitive radiotherapy at our institution.
Yue Ke +6 more
wiley +1 more source
ABSTRACT Objectives Perforated appendicitis commonly results in intra‐abdominal infection requiring prolonged antibiotic therapy. Intraoperative antimicrobial adjuncts are limited, and photodynamic therapy (PDT) may provide a targeted, resistance‐independent approach.
Timothy M. Baran +7 more
wiley +1 more source
Dosimetric end-to-end tests in a national audit of 3D conformal radiotherapy
Background and purpose: Independent dosimetry audits improve quality and safety of radiation therapy. This work reports on design and findings of a comprehensive 3D conformal radiotherapy (3D-CRT) Level III audit.
Joerg Lehmann +12 more
doaj +1 more source

