Results 1 to 10 of about 42 (34)
Radioisotope Dilution Technique for Determination of Vitamin B12 in Foods
Abstract A radioisotope dilution (RID) method for the determination of vitamin B12 is presented. The method combines a standard extraction procedure (AOAC 43.108,12th ed.) with a commercially available RID assay kit. The method was evaluated on a wide range of fortified and unfortified food products.
P J, Casey +3 more
openaire +4 more sources
Highly sensitive assay of HMG-CoA reductase activity by LC-ESI-MS/MS
We have developed a new sensitive and specific nonradioisotope assay method to measure the activity of HMG-CoA reductase, the rate-controlling enzyme in the cholesterol biosynthetic pathway.
Honda Akira +5 more
doaj +1 more source
Akihiro Kuwahata,1,* Muneer Ahmed,2,* Kohei Saeki,3 Shinichi Chikaki,1 Miki Kaneko,1 Wenqi Qiu,1 Zonghao Xin,1 Shinji Yamaguchi,3 Akiko Kaneko,1 Michael Douek,2 Moriaki Kusakabe,3,4 Masaki Sekino1 1Department of Electrical Engineering and Information ...
Kuwahata A +11 more
doaj
A modification to a radioisotopic dilution technique for vitamin B12. [PDF]
E, Gallie, J, Robson
openaire +2 more sources
Serum vitamin B12 from 6 sheep fed a diet containing 0.06 mg cobalt per kg dry matter (DM) was analysed by a radioisotope dilution (RID) technique. The results were compared with values obtained by a microbiological method (Lactobacillus leichmannii - ATCC 7830) specific for "true" vitamin B12.
Mohammed, R., Lamand, M.
openaire +2 more sources
The measurement of total body potassium by the radioisotope dilution technique.
B A, BURROWS, J H, SISSON
openaire +1 more source
Some of the next articles are maybe not open access.
Tissue vitamin B-12 assay by a radioisotope dilution technique
Clinica Chimica Acta, 1975A method is described for the measurement of vitamin B-12 (B-12) in solid tissues by radioisotope dilution (RID) assay. The method is a modivication using double extraction of a serum B-12 RID assay which uses chicken serum as the B-12 binder. The method was developed and tested using human and bat liver specimens.
S V, Van Tonder, J, Metz, R, Green
openaire +4 more sources
A Rapid Radioisotope Dilution Technique for the Accurate Determination of the Cardiac Output
Nuklearmedizin, 1968SummaryA pair of printing scalers was used to record the information obtained by external monitoring of the isotope dilution curve following the intravenous injection of radioiodinated human serum albumin. The first scaler gives the differential count rate of the curve at increments of one second, whereas the second integrates continuously the isotope ...
M A, Razzak, R E, Botti, W J, MacIntyre
openaire +4 more sources
BJOG: An International Journal of Obstetrics & Gynaecology, 1977
SummaryUsing a 51Cr‐labelled red cell dilution technique, the blood loss associated with elective lower segment Caesarean section was measured in 30 patients, half of whom had a previous history of Caesarean section. The blood loss (mean±SD) was 1290±240 ml for first Caesarean sections and 1012±380 ml for repeat operations.
M D, Read, J M, Anderton
openaire +4 more sources
SummaryUsing a 51Cr‐labelled red cell dilution technique, the blood loss associated with elective lower segment Caesarean section was measured in 30 patients, half of whom had a previous history of Caesarean section. The blood loss (mean±SD) was 1290±240 ml for first Caesarean sections and 1012±380 ml for repeat operations.
M D, Read, J M, Anderton
openaire +4 more sources

