Results 91 to 100 of about 736,277 (235)
Low‐voltage FIB‐SEM tomography combined with a image preprocessing pipeline improves phase contrast and enables reliable machine‐learning segmentation of conductive networks in lithium‐ion battery electrodes. Structural descriptors are extracted from segmented images, done semimanually and automated, and compared.
Lisa Beran +6 more
wiley +1 more source
A combined experimental–computational framework identifies energy‐dependent laser absorptivity for NiTi in laser powder‐bed fusion, applicable to conduction and transition modes. Single‐track experiments and thermofluid smoothed particle hydrodynamics simulations are coupled through inverse analysis of melt pool geometry.
Mohamadreza Afrasiabi +3 more
wiley +1 more source
Experiments and thermophysical simulations were conducted to investigate the electron beam powder bed fusion electron beam (PBF‐EB/M) process for the γ′‐strengthened nickel‐based superalloy Inconel 738LC. The results demonstrate the impact of process‐induced microstructural variations on high‐temperature mechanical behavior, providing a basis for ...
Jan Niklas Petenati +11 more
wiley +1 more source
High‐Resolution Corrosion Fingerprinting of Alloy Libraries via Microdroplet Spectroelectrochemistry
Ionic‐liquid microdroplet spectroelectrochemistry enables stable, localized electrochemical measurements over extended timescales. By coupling impedance spectroscopy, wetting analysis, finite‐element simulations, and operando Raman spectroscopy, it disentangles geometrical and electrochemical effects, opening new opportunities for rapid corrosion ...
Ekaterina Kurchavova +3 more
wiley +1 more source
Residual adhesive after electrode loading in adhesive‐assisted resistance spot welding is quantified through a traceable experimental‐to‐digital workflow. Chromatic confocal topography provides calibrated surface‐height data, while OpenCV detects the electrode imprint and integrates adhesive height into comparable volume metrics.
Sung‐Min Wi, Jiangdong Zhao
wiley +1 more source
Comparative Analysis of Anatomical Parameters of the Distal End of the Radius
Background: The distal end of the radius is a critical anatomical structure involved in wrist biomechanics, and its morphometric characteristics are essential for clinical applications such as surgical planning, prosthetic design, and forensic ...
Hussain Saheb Shaik +5 more
doaj +1 more source
Deep‐UV (258 nm) femtosecond pulses enable uniform amorphous silicon writing on Si(100)/(111) with a six‐fold larger fluence amorphization window than NIR methods. Optimized fluence and overlap yield 20–45 nm uniform and continuous amorphous layers. Microscopy shows sharp interfaces, and real‐time reflectivity reveals nanosecond melt–resolidification ...
Wissal Benali +5 more
wiley +1 more source
Background: Treatment of displaced fractures of the distal end of radius has changed over the course of time. This study was conducted to determine the functional and radiological outcome of percutaneous pinning followed by plaster cast for unstable ...
Muhammad shafiq Khan +4 more
doaj
Geometrical modifications on nitrocellulose membranes can result in observable differences in signal intensity relative to a reference membrane (top and bottom left). Using two reference experiments, we have developed a theoretical model that can reproduce the experimentally observed flow changes and provide information on membrane parameters, e.g ...
Maria Dimaki +2 more
wiley +1 more source

