Results 81 to 90 of about 3,723 (222)
The RAD7 radon monitor, based on the electrostatic collection method, is sensitive to humidity during measurements, necessitating the use of a desiccant to maintain the relative humidity in its built-in chamber less than 10 %.
Huiying Li +10 more
doaj +1 more source
Natural Radionuclides and Radon Exhalation Rate in the Soils of Cauvery River Basin
In this study, systematic measurement of activity concentrations of 40 K, 226 Ra, and 232 Th and radon exhalation rate has been done in soil samples of Cauvery River environment.
CS Kaliprasad, PR Vinutha, Y Narayana
doaj +1 more source
The natural radon decay, leakage and back diffusion are the main removal processes of radon from its container. Ignoring these processes leads to underestimate the measured value of radon related parameters like exhalation rate and radium content.
M. Abo-Elmagd
doaj +1 more source
International standardisation work on the measurement of radon in air and water [PDF]
Radon is considered to be the main source of human exposure to natural radiation. As stated by the World Health Organization, the exposure due to the inhalation of indoor radon is much greater than the one via the ingestion of water as radon degasses ...
Ameon, R. +20 more
core
Traceable measurements of the activity concentration in air [PDF]
The nuclear reactions induced by high energetic protons in heavy targets such as UC/sub 2/ and ThC cause a particular, complex radiation protection task at facilities like ISOLDE: the measurement of a mixture of different isotopes of the radioactive ...
Forkel-Wirth, Doris +4 more
core +1 more source
Radon exhalation rate from the latex pillows and its potential exposure to users
Objective: To develop a new system to accurately measure the radon exhalation from the latex pillows, and to estimate its potential exposure to users. Methods: The new system is composed of two loops, the first loop is designed to trap background radon ...
Phachirarat Sola +12 more
doaj +1 more source
Estimation of indoor radon levels using etched track detector
In this investigation, the activity levels of Indoor Radon-222, effective radium contents, exhalation rate of radon, and annual effective dose are reported for different indoor locations (Offices, Laboratories, Meeting rooms, and Storerooms) at two ...
Basma A. El-Badry, Tayseer I. Al-Naggar
doaj +1 more source
Active and passive radon concentration measurements and first-step mapping in schools of Banja Luka, Republic of Srpska [PDF]
Radon concentration measurements were performed in all 25 primary schools in Banja Luka city, the capital of Republika Srpska, during 2011 and 2012, using both active RAD7 continual radon measuring instruments and CR-39 passive (commercially known as ...
CURGUZ Z +5 more
core
Western European N2O emissions: A top-down approach based on atmospheric observations [PDF]
We present a three-year record of continuous gas chromatographic nitrous oxide (N2O) observations performed at the urban station Heidelberg (Germany) together with weekly flask data from a remote continental site, Schauinsland (Black Forest, Germany ...
Glatzel-Matteier, Holger +4 more
core +1 more source
Radon exhalation and emanation assessments in the Transdanubian Central Mountain in Hungary
Objective: To determine the radium-226 activity concentration, the massic radon exhalation rate and emanation factor of 55 soil samples from the Central Transdanubian Mountains in Hungary as well as possible radon exhalation hotspots in the sampling area
Maté Novák +6 more
doaj +1 more source

