Results 291 to 300 of about 3,724,057 (366)
Abstract Background The dose‐averaged linear energy transfer (LETD) in proton therapy (PT) has in pre‐clinical studies been linked to the relative biological effectiveness (RBE) of protons. Until recently, the most common PT delivery method in prostate cancer has been double‐scattered PT, with LETD only available through dedicated Monte Carlo (MC ...
Rasmus Klitgaard+7 more
wiley +1 more source
Retrospective study on NIPT or NIPT plus combined with ultrasound in screening fetal chromosomal abnormalities. [PDF]
Chen M+7 more
europepmc +1 more source
A review of artificial intelligence in brachytherapy
Abstract Artificial intelligence (AI) has the potential to revolutionize brachytherapy's clinical workflow. This review comprehensively examines the application of AI, focusing on machine learning and deep learning, in various aspects of brachytherapy.
Jingchu Chen+4 more
wiley +1 more source
Genome-wide profiling and functional characterization of circular RNAs in neural development and injury: insights from a rat model research. [PDF]
Yang J+11 more
europepmc +1 more source
Abstract Purpose Single‐isocenter multitarget (SIMT) radiosurgery has become increasingly popular as advancement in planning and delivery systems have made this approach clinically viable. With targets varying in size and distance from isocenter, SIMT plans are highly complex with dynamic multileaf collimator (MLC) motion.
Hem Moktan+3 more
wiley +1 more source
Evaluation of the effect of metal stents on dose perturbation in the carbon beam irradiation field
Abstract Propose Carbon ion therapy is indicated for cases in which stents have been inserted, such as bile ducts, but the effect of metal stents on carbon ion therapy is unclear. In this study, the dose perturbation of carbon ion therapy caused by metallic bile duct stents was evaluated by dosimetry. Materials and methods Five different types of metal
Yuya Miyasaka+8 more
wiley +1 more source
miR-27b-3p modulates liver sinusoidal endothelium dedifferentiation in chronic liver disease. [PDF]
Abad-Jordà L+9 more
europepmc +1 more source
Abstract Purpose The dual‐layer multileaf collimator (MLC) in Halcyon adds complexities to the dose calculation process owing to the variability of dosimetric characteristics with leaf motion. Recently, an enhanced leaf model (ELM) was developed to refine the MLC model in the Eclipse treatment planning system. This study investigates the performance of
Ryohei Miyasaka+6 more
wiley +1 more source