Validation of rebound tonometry for intraocular pressure measurement in the rabbit
Experimental Eye Research, 2014Rabbits play a growing role in research into glaucoma surgical models and ocular drug delivery models. However, the lack of an accurate method for measuring intraocular pressure (IOP) in this animal has been a significant deficit. In this study we validated the use of the TonoVet rebound tonometer and provide conversion tables for its use in rabbits ...
Hong Zhang +5 more
openaire +2 more sources
Ophthalmology, 2019
Abstract The agreement between ICare PRO and Perkins tonometers was clinically acceptable when IOP was ≤19 mm Hg and the difference was clinically not acceptable when IOP was >19 mm Hg in pediatric glaucomas with clear and scarred corneas.
Swathi Vallabh Badakere +6 more
openaire +2 more sources
Abstract The agreement between ICare PRO and Perkins tonometers was clinically acceptable when IOP was ≤19 mm Hg and the difference was clinically not acceptable when IOP was >19 mm Hg in pediatric glaucomas with clear and scarred corneas.
Swathi Vallabh Badakere +6 more
openaire +2 more sources
American Journal of Ophthalmology, 2016
To investigate agreement in intraocular pressure (IOP) measurements among Icare rebound tonometry, Tonopen tonometry, and Goldmann applanation tonometry following vitreoretinal surgery.Reliability analysis of tonometers.Fifty-eyes of 50 adults undergoing vitreoretinal surgery were enrolled.
Dilraj S. Grewal +8 more
openaire +2 more sources
To investigate agreement in intraocular pressure (IOP) measurements among Icare rebound tonometry, Tonopen tonometry, and Goldmann applanation tonometry following vitreoretinal surgery.Reliability analysis of tonometers.Fifty-eyes of 50 adults undergoing vitreoretinal surgery were enrolled.
Dilraj S. Grewal +8 more
openaire +2 more sources
Bulletin de la Societe belge d'ophtalmologie, 2007
The Proview phosphene (eye-pressure) tonometer and the Rebound tonometer ICare are relatively new devices basically different from the Goldmann applanation tonometry (GAT). Both technologies will be presented in this review with respect to their principle, their technique, their advantages and limits, as well as their accuracy, the IOP measurements ...
openaire +1 more source
The Proview phosphene (eye-pressure) tonometer and the Rebound tonometer ICare are relatively new devices basically different from the Goldmann applanation tonometry (GAT). Both technologies will be presented in this review with respect to their principle, their technique, their advantages and limits, as well as their accuracy, the IOP measurements ...
openaire +1 more source
[Rebound tonometry after vitreoretinal surgery].
Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft, 2016The aim of this study was to analyze the practicability and comparability of the Icare rebound tonometer (RT) versus the Schiötz indentation tonometer (SIT) and the Goldmann applanation tonometer (GAT) for measuring intraocular pressure (IOP) in patients after pars plana vitrectomy (PPV).A total of 100 eyes from 100 patients who underwent vitreoretinal
A, Rosentreter +5 more
openaire +1 more source
[Rebound tonometry and applanation tonometry during narcosis investigation of pediatric glaucoma].
Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft, 2011A comparison of intraocular pressure (IOP) in cases of infantile glaucoma during general anesthesia was carried out by measurement with the iCare rebound tonometer (RBT) and a handheld applanation tonometer (Perkins).A total of 45 eyes from pediatric patients with childhood glaucoma were included in this prospective trial. Bland-Altman plots and linear
A, Rosentreter +4 more
openaire +1 more source
[Comparison of Rebound tonometry versus Perkins tonometry in the supine glaucoma patient].
Klinische Monatsblatter fur Augenheilkunde, 2011The aim of this study was to evaluate the concordance of intraocular pressure (IOP) measurements in the supine glaucoma patient using a Perkins applanation tonometer (PAT) compared to the iCare® rebound tonometer (RT), a hand-held device requiring no local anaesthesia.73 left eyes of 73 glaucoma patients were included in this consecutive case study and
A M, Schild +7 more
openaire +1 more source
Rebound-Tonometrie mit sterilisierten Sonden
Die Ophthalmologie, 2023Daniel M. Handzel +4 more
openaire +1 more source