Results 121 to 130 of about 3,902 (291)

Protection of Short Transmission Lines Using Microprocessor-Based Distance Relay [PDF]

open access: yes, 2004
Distance protection is used for the protection of transmission or sub-transmission lines, usually 33 KV, 66 KV and 132 KV lines. A distance relay measures the distance between the relay location and the point of fault in terms of impedance, reactance ...
Mohammed Ali, Hussain Fadhil
core  

Enabling pandemic‐resilient healthcare: Narrowband Internet of Things and edge intelligence for real‐time monitoring

open access: yesCAAI Transactions on Intelligence Technology, EarlyView.
Abstract The Internet of Things (IoT) in deploying robotic sprayers for pandemic‐associated disinfection and monitoring has garnered significant attention in recent research. The authors introduce a novel architectural framework designed to interconnect smart monitoring robotic devices within healthcare facilities using narrowband Internet of Things ...
Md Motaharul Islam   +9 more
wiley   +1 more source

HSL‐CFS: Hybrid stacked learning with cooperative feature selection for cyberattack detection in smart grids

open access: yesEnergy Conversion and Economics, EarlyView.
Abstract An effective method for detecting cyberattacks is essential to the security of smart grids (SGs). In SGs, data from both cyber and physical domains can support attack detection. However, existing works insufficiently consider the heterogeneity, high dimensionality, and cross‐domain correlations of multi‐source data, affecting model ...
Qize Gao   +5 more
wiley   +1 more source

Improving Protection Reliability of Multi-source Meshed Power systems by An Automation-assisted Overcurrent Protection

open access: yes
The overcurrent protection of multi-source meshed power systems has been a challenge since their emergence owing to the low fault-current seen by the backup protection.
Yazdaninejadi, Amin   +3 more
core   +1 more source

Adaptive multivariable relay protection of reconfigurable distribution networks

open access: yes, 2019
Version of relay protection construction of relative selectivity is proposed, which allows increasing its technical perfection and reliability in microgrids with distributed generation sources.
Anton Petrov   +2 more
core   +1 more source

Analysis of the Anti High‐Altitude Electromagnetic Pulse Interference Ability of Relay Protection Devices

open access: yesHigh Voltage, EarlyView.
ABSTRACT High altitude electromagnetic pulse (HEMP), as a steep slope and high amplitude instantaneous energy shock, has stronger coupling and greater destructive power, which can easily cause the secondary control device of the substation to malfunction.
Long Jin   +5 more
wiley   +1 more source

800 kV Fast Circuit Breaker: Mechanical Coupling Modelling, Buffer Design and Development

open access: yesHigh Voltage, EarlyView.
ABSTRACT The 800 kV fast circuit breaker (CB) used in ultra‐high voltage (UHV) converter transformer can reduce the total breaking time to 25 ms. It significantly improves the action speed and breaking capacity of the CB, with promising broad application prospects.
Enyuan Dong   +6 more
wiley   +1 more source

Enhancing Hydrophobic Stability of Silicone Rubber Insulators Under High‐Voltage Direct Current Stress Through Optimised Nano‐Fumed Silica Surface Area: A Dynamic Drop Test Study

open access: yesHigh Voltage, EarlyView.
ABSTRACT The long‐term hydrophobic stability of silicone rubber (SiR) insulators is essential for their reliability in high‐voltage direct current (HVDC) applications. This study investigates the effect of nano‐silica fillers with varying specific surface areas (SSA = 120, 200 and 300 m2/g) and different concentrations of alumina trihydrate (ATH ...
Mahmoud A. Ali   +3 more
wiley   +1 more source

Performance Evaluation of Overcurrent Protection Relay Based on Relay Operation Time (ROT)

open access: yes, 2018
Protection system plays an important role in detecting the presence of disorders and may prevent damage that can caused interference. Thus, the reliability of the system to maintain continuity of supply to the load will be improved.
Hanaffi, Farhan; Centre for Robotic and Industrial Automation (CeRIA), Fakulti Kejuruteraan Elektrik, Universiti Teknikal Malaysia Melaka (UTeM)   +3 more
core  

South Asian Bodies at British Borders in the 1970s: From the Ugandan Asian ‘Stateless Husbands’ to ‘Virginity Testing’

open access: yesGender &History, EarlyView.
ABSTRACT This article looks at two critical moments in British immigration – the case of the ‘stateless’ Ugandan Asian husbands, whose wives successfully argued for their entry in Britain in 1973 and the ‘virginity test’ performed on Mrs K at Heathrow Airport in 1979.
Antara Datta, Jinal Parekh
wiley   +1 more source

Home - About - Disclaimer - Privacy