Results 41 to 50 of about 1,140 (275)
Electrical safety of resonant grounding
The resonant grounding is one of the possible methods of system neutral grounding for the medium-voltage distribution. IEEE standards do define this grounding configuration, but important advantages and drawbacks of the resonant grounding might not be ...
Mitolo M. +5 more
core +1 more source
Accurate fault area localization is a challenging problem in resonant grounding systems (RGSs). Accordingly, this paper proposes a novel two-stage localization method for single-phase earth faults in RGSs.
Jingwen Chen +5 more
doaj +1 more source
Control Method of Single-phase Inverter Based Grounding System in Distribution Networks [PDF]
The asymmetry of the inherent distributed capacitances causes the rise of neutral-to-ground voltage in ungrounded system or high resistance grounded system.
L. Yan +11 more
core +1 more source
Optimisation Method for Pre-set Arc Suppression Coil Damping Resistors Enhancing Ground Fault Detection [PDF]
As a key component of pre-set arc suppression coil, the damping resistor is currently configured primarily to suppress series resonance overvoltage and prevent protection maloperation during normal operation.
ZHANG Jianbin +4 more
doaj +1 more source
With the continuous development of artificial intelligence technology, the value of massive power data has been widely considered. Aiming at the problem of single-phase-to-ground fault line selection in resonant grounding system, a fault line selection ...
Haixia Zhang, Wenao Cheng
doaj +1 more source
Analysis of the impact on the grounding system in 110 kv grid during bottom-up network restoration
6 S.The purpose of this research is to study how the grounding on the high voltage end (110 kV) is impacted during a bottom-up network restoration process in different islanding configurations.
Banerjee, G., Braun, M.
core +1 more source
In this paper, a full-wave approach based on the method of moment (MoM) is proposed to investigate the harmonic impedance of a tower and its connected ground electrode in the frequency domain.
Bak, Claus Leth +4 more
core +1 more source
Optimizing photoactivation of PA‐mCherry for optical pooled CRISPR screens
Photoactivatable PA‐mCherry finds widespread use to optically tag individual cells. However, confocal 405 nm UV laser‐scanning (normal scan) is much less efficient than widefield UV illumination, limiting the use of PA‐mCherry on confocal instruments. We remedy this limitation by reporting that rapid and repeated confocal scanning with a low‐intensity,
Sravasti Mukherjee +3 more
wiley +1 more source
UiO‐66(Zr) metal–organic frameworks are chemically stable, biocompatible, and highly tunable nanomaterials. Their modular structure enables controlled drug delivery, multimodal bioimaging, and light‐activated photodynamic therapy, supporting integrated diagnostic and therapeutic (theranostic) applications in cancer and biomedical research.
Veronika Huntošová +2 more
wiley +1 more source
Quantum algorithm for preparing the ground state of a system via resonance transition [PDF]
AbstractPreparing the ground state of a system is an important task in physics. We propose a quantum algorithm for preparing the ground state of a physical system that can be simulated on a quantum computer. The system is coupled to an ancillary qubit, by introducing a resonance mechanism between the ancilla qubit and the system, and combined with ...
openaire +3 more sources

