Results 21 to 30 of about 1,030 (244)
This paper presents the design of a small antenna for use in a wireless local area network (WLAN) and Wi-fi 6E on a narrow-border laptop. The dimensions of the antenna are 43 × 3 × 0.4 mm3, and it features a grounding system simulated by a 200 × 260 mm2 ...
Wei-Chiang Jhang, Jwo-Shiun Sun
doaj +1 more source
Optical Feshbach resonances and ground-state-molecule production in the RbHg system [PDF]
We present the prospects for photoassociation, optical control of interspecies scattering lengths and finally, the production of ultracold absolute ground state molecules in the Rb+Hg system. We use the "gold standard" ab initio methods for the calculations of ground (CCSD(T)) and excited state (EOM-CCSD) potential curves.
Borkowski, Mateusz +4 more
openaire +2 more sources
Research of characteristics of transient pulse in coal mine resonant grounding system
By means of deduction of zero-sequence current expressions when single-phase grounding fault occurs in single substation mode and multi-substation mode of coal mine resonant grounding system, polarity relationship between transient pulse of fault line ...
WANG Jinhong
doaj +1 more source
Through analyzing the transient components and transient characteristics in transient zero-sequence current (TZSC), a novel fault feeder detection method based on the transient correlation of non-power frequency components (NPFCs) for the resonant ...
Kewen Wei +4 more
doaj +1 more source
Ferromagnetic resonance over-voltage identification method based on Gram angle field
In neutral point non-grounding systems with 35 kV and below, ferromagnetic resonance over-voltage faults often occurs, which brings safety hazards to power systems.
Qiong Li +3 more
doaj +1 more source
Accurate fault area localization is a challenging problem in resonant grounding systems (RGSs). Accordingly, this paper proposes a novel two-stage localization method for single-phase earth faults in RGSs.
Jingwen Chen +5 more
doaj +1 more source
Optimisation Method for Pre-set Arc Suppression Coil Damping Resistors Enhancing Ground Fault Detection [PDF]
As a key component of pre-set arc suppression coil, the damping resistor is currently configured primarily to suppress series resonance overvoltage and prevent protection maloperation during normal operation.
ZHANG Jianbin +4 more
doaj +1 more source
With the continuous development of artificial intelligence technology, the value of massive power data has been widely considered. Aiming at the problem of single-phase-to-ground fault line selection in resonant grounding system, a fault line selection ...
Haixia Zhang, Wenao Cheng
doaj +1 more source
When the earth faults occur in different phases of two feeders connected to the same bus in the resonant grounding system, the conventional fault line selection devices are inaccurate.
HAN Jie +5 more
doaj +1 more source
Microbiome‐blood–brain barrier interactions in aging — mechanisms and therapeutic potential
Aging reshapes the gut microbiome (↓SCFA‐producing commensals; ↑pro‐inflammatory outputs), shifting circulating metabolites (↓SCFAs; ↑LPS, ↑TMAO, ↑PAA) that act at the BBB to increase nonspecific transcytosis, alter transport, and promote astrocyte reactivity, heightening brain vulnerability.
Daniel Cuervo‐Zanatta +3 more
wiley +1 more source

