Flexible composite suppression method for ground arc in resonant grounding system
A currentāvoltage composite controller for an arc suppression inverter is designed. The current and voltage at the fault point are reduced by injecting current and regulating the neutral point voltage to completely eliminate the risk of fire and ...
Jianzhang You +3 more
doaj +2 more sources
Faulty Section Location Method Based on Dynamic Time Warping Distance in a Resonant Grounding System
When a single-phase grounding fault occurs in a resonant grounding system, the determination of the fault location remains a significant challenge due to the small fault current and the instability of the grounding arc.
Yu He +6 more
doaj +3 more sources
A novel approach for high impedance fault detection in resonant grounding systems based on statistical characteristics [PDF]
High impedance faults (HIF) in the resonant grounding system of distribution networks pose significant challenges for traditional protection devices, which often fail to detect and eliminate these faults promptly. The difficulty in setting an appropriate
Qinglin Meng +4 more
doaj +2 more sources
Simulation Analysis of Single-phase Grounding Fault of Resonant Grounding System
For problem of difficult line selection caused by small current of fault line with uncertain direction when single-phase grounding fault happens in resonant grounding system, the paper theoretically analyzed change law of zero-sequence voltage and zero ...
LI Hui, TANG Yi, SUN Chang-qing
doaj +1 more source
MATLAB Power System Simulation of Resonant Grounding Fault
AbstractIn order to handle the situation of power system grounding fault better, this paper built the mathematical model of power system resonance grounding fault based on the resonance grounding principle. And simulated the resonance processes by using MATLAB/SIMULINK/ SIMPOWERSYSTEM (SPS) software.
Chun-wen, Yang +3 more
openaire +3 more sources
The identification of faulty feeder for single-phase high impedance faults (HIFs), especially in resonant grounding distribution system (RGDS), has always been a challenge, and existing faulty feeder identification techniques for HIFs suffer from some ...
Tao Tang +3 more
doaj +3 more sources
Research of characteristics of transient pulse in coal mine resonant grounding system
By means of deduction of zero-sequence current expressions when single-phase grounding fault occurs in single substation mode and multi-substation mode of coal mine resonant grounding system, polarity relationship between transient pulse of fault line ...
WANG Jinhong
doaj +2 more sources
Single-Line-to-Ground Fault Location in Resonant Grounded Systems Based on Fault Distortions [PDF]
Under single-line-to-ground (SLG) faults, the voltages and currents in resonant grounded systems will inevitably be distorted. To locate the faults quickly and accurately, this paper proposes a location method based on fault distortions. The faulty phase is firstly detected according to the first SLG fault feature below, and then the faulty feeder and ...
Yougen Chen +3 more
openaire +2 more sources
Magnetically coupled resonant technology is a novel method for solving the breakpoint locating of power grounding grid. But the method can only detect breakpoints of a single mesh grounding grid at present.
Weihua Chen +3 more
doaj +1 more source
In the urban distribution network, due to the wide application of underground cables, the traditional resonant grounding system has gradually been unable to match the increasing fault current amplitude, real-time compensation and harmonic component ...
Kangli Liu +3 more
doaj +1 more source