Dyssynchrony without dysfunction: Left bundle branch block does not acutely reduce cardiac output
Abstract figure legend Six electromechanical in silico heart models were simulated under healthy and pure acute left bundle branch block (LBBB) conditions. LBBB induced electrical dyssynchrony and increased left ventricular free wall strain, while the right and left ventricular ejection fraction remained relatively unchanged.
Carola Kruthoff +6 more
wiley +1 more source
Formal Framework for the Evaluation of Waveform Resynchronization Algorithms
Part 4: AlgorithmsInternational audienceIn side-channel analysis, the waveforms can be acquired misaligned. Several algorithms have been put forward to resynchronize signals, as a pretreatment before the attack proper.
Jean-Luc Danger +7 more
core +1 more source
This prospective study demonstrates that regionalized high‐volume cardiac pacing programmes, supported by structured mentorship, are safe and efficient. Regional centres can successfully navigate the surgical learning curve, achieving safety outcomes non‐inferior to tertiary standards while eliminating geographical barriers for elderly patients ...
Sergejs Pikta +4 more
wiley +1 more source
Prognostic Significance and Factors Associated With Worsening LV Dilatation in Heart Failure
Among patients with a hospitalization or ED visit for HF and at least two echocardiograms at least 6 months apart, failure to decrease LVESD by at least 3.13% or an increase in LVEDD of 1.33% were associated with the composite of all‐cause death, HF hospitalization, and ED visits for HF. Figure created using Canva and Servier Medical Art. ED, emergency
Tauben Averbuch +6 more
wiley +1 more source
Cardiac resynchronization therapy [PDF]
Coronary venous anatomy can make successful implantation of a cardiac resynchronization therapy device difficult or impossible. The aim of this review is introduce an interventional approach with many techniques and tools that are needed to be learned ...
Nestor López-Cabanillas, Seth Worley
core
This statement of the Japanese Heart Rhythm Society (JHRS) provides comprehensive guidance for medical professionals and device manufacturers involved in RM. ABSTRACT Remote monitoring (RM) has been established as a standard tool for the management of patients with cardiac implantable electronic devices (CIEDs), offering advantages such as early event ...
Eiichi Watanabe +10 more
wiley +1 more source
Device‐detected atrial high‐rate episodes (AHREs) lasting ≥ 6 min identify a transient period of increased clinical risk in ICD patients. During the 60‐day peri‐AHRE period, risks of appropriate ICD shock, any appropriate ICD therapy, and cardiac hospitalization were significantly increased.
Nanna Nørgaard +3 more
wiley +1 more source
The molecular fingerprint of cardiac dyssynchrony and cardiac resynchronization therapy
: To date, cardiac resynchronization therapy remains the only treatment that enhances systolic function while improving long-term outcome and survival.
Vrints, Christiaan +2 more
core
Chlorhexidine or Povidone‐Iodine for CIED Procedures? Lessons From CHLOVIS and WRAP‐IT
Pacing and Clinical Electrophysiology, EarlyView.
Antoine Da Costa +4 more
wiley +1 more source
This 30‐year retrospective study of pediatric permanent pacing found acceptable long‐term device complication rates, with epicardial leads used predominantly. Pacing‐induced cardiomyopathy occurred only in children with congenital heart disease, highlighting the need for individualized pacing strategies in this cohort and long‐term echocardiographic ...
Jiahui Charmaine Chan +12 more
wiley +1 more source