Results 191 to 200 of about 200,471 (302)

Influence of Test Temperature and Test Frequency on Fatigue Life of Aluminum Alloy EN AW‐2618A

open access: yesAdvanced Engineering Materials, EarlyView.
The influence of test temperature and test frequency on the fatigue life of EN AW‐2618A is investigated. High‐cycle fatigue tests are performed at different test temperatures and frequencies on the 1000 h/230°C overaged state. Both test parameters reduce fatigue life due to time‐dependent damage mechanisms.
Ying Han   +5 more
wiley   +1 more source

Creep Properties and Deformation Mechanism of Additively Manufactured NiAl‐CrMo Composites

open access: yesAdvanced Engineering Materials, EarlyView.
Additively manufactured NiAl‐CrMo composites contain numerous interfaces and cell boundaries that control their creep response. At 700°C under high applied stress, creep is dominated by dislocation‐controlled power‐law mechanisms. At 800°C–900°C and lower stresses, creep is primarily diffusion‐controlled along cell boundaries.
Jan Vollhüter   +9 more
wiley   +1 more source

Evaluation of Plasticity and Creep Parameters From Tensile Stress–Strain Data for a Range of Strain Rates

open access: yesAdvanced Engineering Materials, EarlyView.
This plot compares experimental tensile stress–strain curves (with 4 different strain rates) and corresponding modelled curves (obtained using the optimised sets of Voce and Miller–Norton parameter values shown). The inferred M‐N values, characterizing the creep, are very similar to those obtained via conventional creep testing.
S. Ooi, R. P. Thompson, T. W. Clyne
wiley   +1 more source

Asymmetric Total Synthesisof (−)-PsychotriadineFeaturing [3,3]-Rearrangement and Stereo-Controllable Ring-Contraction

open access: green
Qingxing Yang (18718577)   +4 more
openalex   +1 more source

Direct Metal Deposition of Graphene–Ti28Nb35.4Zr Matrix Composites With Enhanced Mechanical, Corrosion, and Biocompatibility Properties for Bone Implants

open access: yesAdvanced Engineering Materials, EarlyView.
Graphene nanoplatelet (0.1 wt.%) reinforcement significantly enhances the performance of β Ti‐28Nb‐35.4Zr alloy. Grain refinement, reduced water contact angle, and improved surface characteristics promote osteoblast adhesion and complete surface coverage after 7 days.
Khurram Munir   +5 more
wiley   +1 more source

Cathodic Cage Plasma Deposition of Nanostructured Cu–Fe–Se Coatings on Poly(methyl Methacrylate)

open access: yesAdvanced Engineering Materials, EarlyView.
Nanostructured Cu–Fe–Se coatings are deposited on PMMA by a modified cathodic cage plasma process, enabling low‐temperature deposition on polymer substrates. A transition from discontinuous to compact morphology is observed with temperature, with optimal properties at 200°C, where improved CuFeSe2‐type bonding, lowest sheet resistance, and favorable ...
V. S. S. Sobrinho   +8 more
wiley   +1 more source

Home - About - Disclaimer - Privacy