Results 51 to 60 of about 4,438 (211)
Low‐frequency performance of openable flexible double‐loop Rogowski coil
Double‐loop Rogowski coils have become increasingly popular in the market because of their high sensitivity and flexible usage compared to their extended single‐loop coils. Due to the high number of turns (thousands) and its small turn diameter (
Xiaoyu Liu, Hui Huang, Chaoqun Jiao
doaj +1 more source
The work is devoted to the development and modelling of the system of pulse current measurement during high-voltage tests and experiments. The proposed measurement system is based on the application of Rogowski coil with non-inverting integrator.
Vladimir V. Kochetkov +2 more
doaj +1 more source
Hybrid Sensing of Internal and Surface Partial Discharges in Air-Insulated Medium Voltage Switchgear
Partial discharge (PD) measurements have proved their reliability for health monitoring of insulation systems in power system components including synchronous generators, power transformers, switchgear and cables etc.
Ghulam Amjad Hussain +4 more
doaj +1 more source
Numerická analýza a simulace Rogowského cívky [PDF]
This work illustrates an analysis of Rogowski coils for power applications, when operating under non ideal measurement conditions. The developed numerical model, validated by comparison with other methods and experiments, enables to investigate the ...
Hussion, M Walid
core
Cryogenic magnetometer research at Twente University of Technology [PDF]
In 1982 we started the project ‘Cryogenic Magnetometers’ with the aim to develop SQUID-magnetometers appropriate to a large variety of applications.
Brake, H.J.M. ter, Flokstra, J.
core +3 more sources
Equivalent Test Method for Fault Ride‐Through of Integrated Energy‐consuming MMC Modules
This paper proposes an equivalent assessment index covering the entire fault ride‐through process, taking the integrated energy‐consuming MMC valve as the research object, and solves the problem of the lack of assessment index for the fault ride‐through equivalent test.
Ying Li +7 more
wiley +1 more source
Frequency response analysis is widely used as a method for the offline diagnosis of winding deformations in power transformers. To apply it to a working transformer, people need to determine how to inject the excitation signal and measure the response ...
Yangchun Cheng +7 more
doaj +1 more source
Local magnetic measurements in magnetic circuits with highly nonuniform electromagnetic fields [PDF]
In this paper, local magnetic measurements are carried out in magnetic circuits with highly non uniform electromagnetic field patterns, including excitation winding and/or air gaps, as in the case of rotating electrical machines.
Dupré, Luc +1 more
core
Towards the text compression based feature extraction in high impedance fault detection [PDF]
High impedance faults of medium voltage overhead lines with covered conductors can be identified by the presence of partial discharges. Despite it is a subject of research for more than 60 years, online partial discharges detection is always a challenge,
Fulneček, Jan +4 more
core +1 more source
This paper proposes a non‐contact method for measuring the turn‐off time of insulated‐gate bipolar transistor (IGBT) devices in modular multilevel converters (MMC) submodules, using the decay of load‐side common‐mode current. The technique leverages existing current‐sensing infrastructure and avoids intrusive modifications, enabling real‐time ...
Jiyun Liu +7 more
wiley +1 more source