Results 101 to 110 of about 4,944 (303)

Research on Key Parameters of Building Load Model for Dynamic Performance Measurement of Air Conditioner

open access: yesZhileng xuebao
Given that the steady-state condition measurement in the laboratory cannot fully reflect the actual performance issues of air conditioners, the dynamic performance measurement of room air conditioners based on virtual buildings has become a current ...
Gao Yuping   +7 more
doaj  

EER Improvement for Room Air-Conditioners in Saudi Arabia

open access: yesEnergy and Power Engineering, 2012
This paper demonstrates the possibility of achieving a higher Energy Efficiency Ratio (EER) for Room Air Conditioners (RACs) that complies with the Saudi energy efficiency standards and satisfies the energy conservation requirements for the Saudi Building Code (SBC).
openaire   +2 more sources

Current Status and Challenges in Data Collection for Aerospace Coatings Deposited by Plasma Spraying

open access: yesAdvanced Engineering Materials, EarlyView.
An innovative approach has been integrated into the GRENAT project to optimize plasma spraying and coating performance. Raw materials are accelerated and melted in the plasma generated by torches, creating coatings. Monitoring sensors collect process data which are combined with ex situ characterization data.
Lila Randriamananjara   +8 more
wiley   +1 more source

Development of Refrigeration Oil for Use With R32

open access: yes, 2012
R410A, which has a high GWP (global warming potential) of roughly 2000, is widely used in refrigeration systems today. Various low GWP alternative refrigerants have been investigated as part of the effort to stop global warming. One such refrigerant, R32,
Takigawa, Katsuya   +2 more
core  

Air conditioner operation behavior based on skin temperature in a classroom

open access: yes, 2020
A total of 25 college students participated as subjects to elucidate when they turned ON/OFF the air-conditioner based on thermal environment and skin temperature.
임재한
core  

Soft Mechanical‐Electrical Logic Using Liquid Metal‐Filled 3D‐Printed Architectures

open access: yesAdvanced Engineering Materials, EarlyView.
We present 3D‐printed soft mechanical–electrical logic elements that use liquid metal–filled silicone tubes actuated by thermoplastic polyurethane/polylactic acid (TPU/PLA) architectures to produce Boolean operations. Complementary normally open and normally closed unit cells perform repeatable binary transitions and can be combined into more complex ...
Christoph Lehmann   +2 more
wiley   +1 more source

Prediction of Dehumidification Amount of Room Air Conditioner

open access: yes, 2007
Room air conditioner is generally used for cooling in a house and removes sensible heat and moisture from indoor air. The room air conditioner doesn\u27t control indoor humidity, because it operates to make the indoor air temperature into the preset ...
渡邉, 大祐   +7 more
core  

Working Model of Refrigerator cum Air conditioner

open access: yes, 2017
This working model refrigeration cum air conditioner is a device that performs both task at same time of cooling refrigeration cabin and room.
, Sharma Vivekkumar Kiritbhai
core   +1 more source

Direct Metal Deposition of Graphene–Ti28Nb35.4Zr Matrix Composites With Enhanced Mechanical, Corrosion, and Biocompatibility Properties for Bone Implants

open access: yesAdvanced Engineering Materials, EarlyView.
Graphene nanoplatelet (0.1 wt.%) reinforcement significantly enhances the performance of β Ti‐28Nb‐35.4Zr alloy. Grain refinement, reduced water contact angle, and improved surface characteristics promote osteoblast adhesion and complete surface coverage after 7 days.
Khurram Munir   +5 more
wiley   +1 more source

Electrochemical Behavior of Flame‐Sprayed Sc‐Doped AlCoCrFeMo High‐Entropy Alloy Coatings in 3.5% Sodium Chloride Solution

open access: yesAdvanced Engineering Materials, EarlyView.
Scandium (Sc)‐doped AlCoCrFeMo HEA coatings are fabricated via flame spraying with 0.1, 0.3, and 0.5 wt% Sc additions. Among these, the HEA‐Sc0.3 coating exhibits the highest corrosion resistance, indicated by a more positive corrosion potential and lower current density.
Pankaj Kumar   +7 more
wiley   +1 more source