Results 11 to 20 of about 11,899 (214)

Numerical Study and Optimization of a Novel Piezoelectric Transducer for a Round-Window Stimulating Type Middle-Ear Implant

open access: yesMicromachines, 2019
Round window (RW) stimulation is a new application of middle ear implants for treating hearing loss, especially for those with middle ear disease. However, most reports on it are based on the use of the floating mass transducer (FMT), which was not ...
Houguang Liu   +2 more
exaly   +3 more sources

The relationship between round window and ear canal Cochlear microphonic

open access: yesLaryngoscope Investigative Otolaryngology, 2022
Hypothesis Cochlear microphonic recorded at ear canal (CM‐EC) can be a substitute for the one recorded at round window (CM‐RW). Background Almost all clinics do not measure tone‐burst evoked CM due to technical difficulty although it can provide more ...
Yongqiang Yu
exaly   +2 more sources

Inner Ear Malformations with Transitional Forms between Cochlear Hypoplasia and Common Cavity: Embryological Insights, Imaging Characteristics, and Cochlear Implantation Strategies [PDF]

open access: yesJournal of Otology
ObjectivesTo investigate the imaging characteristics, surgical approaches, and outcomes of cochlear implantation (CI) in patients with special inner ear malformations (IEMs) that show transitional forms between cochlear hypoplasia (CH) and common cavity (
Shujin Xue   +6 more
doaj   +2 more sources

Development and In-Silico and Ex-Vivo Validation of a Software for a Semi-Automated Segmentation of the Round Window Niche to Design a Patient Specific Implant to Treat Inner Ear Disorders

open access: yesJournal of Imaging, 2023
The aim of this study was to develop and validate a semi-automated segmentation approach that identifies the round window niche (RWN) and round window membrane (RWM) for use in the development of patient individualized round window niche implants (RNI ...
Ziwen Gao, Samuel John, Thomas Lenarz
exaly   +3 more sources

Design Study of a Round Window Piezoelectric Transducer for Active Middle Ear Implants

open access: yesSensors, 2021
This report describes the design of a new piezoelectric transducer for round window (RW)-driven middle ear implants. The transducer consists of a piezoelectric element, gold-coated copper bellows, silicone elastomer (polydimethylsiloxane, PDMS), metal ...
Dong Ho Shin, Shin Dong Ho
exaly   +3 more sources

Simulation-Based Study on Round Window Atresia by Using a Straight Cochlea Model with Compressible Perilymph

open access: yesAcoustics, 2022
The sound stimulus received by the pinna is transmitted to the oval window of the inner ear via the outer ear and middle ear. Assuming that the perilymph in the scala vestibuli and scala tympani is compressible, we report that the sound wave generated in
Wenjia Hong, Yasushi Horii
doaj   +1 more source

Fluid-solid coupling model and biological features of large vestibular aqueduct syndrome

open access: yesFrontiers in Bioengineering and Biotechnology, 2023
Objective: Computed tomography (CT) images of the temporal bone of large vestibular aqueduct syndrome (LVAS) patients were used to establish 3D numerical models based on the structure of the inner ear, which are, in turn, used to construct inner ear ...
Zewen Chen   +5 more
doaj   +1 more source

Sonoporation of the Round Window Membrane on a Sheep Model: A Safety Study

open access: yesPharmaceutics, 2023
Sonoporation using microbubble-assisted ultrasound increases the permeability of a biological barrier to therapeutic molecules. Application of this method to the round window membrane could improve the delivery of therapeutics to the inner ear.
Sandrine Kerneis   +10 more
doaj   +1 more source

Effect of Underwater Insertion on Intracochlear Pressure

open access: yesFrontiers in Surgery, 2020
Background: The importance of intracochlear pressure during cochlear electrode insertion for the preservation of residual hearing has been widely discussed.
Conrad Riemann   +2 more
doaj   +1 more source

Gentamicin delivery to the inner ear: Does endolymphatic hydrops matter? [PDF]

open access: yesPLoS ONE, 2018
INTRODUCTION:Middle ear application of gentamicin is a common medical treatment for uncontrolled Ménière's disease. The objective of the study was to evaluate the impact of endolymphatic hydrops on inner ear delivery.
Pedro Marques   +3 more
doaj   +1 more source

Home - About - Disclaimer - Privacy