Results 191 to 200 of about 22,771 (305)

Prospective Head Motion Correction in T1‐ and T2‐Weighted Long Echo Train Sequences Using Servo Navigation

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To integrate MR‐based servo navigation in MPRAGE and 3D‐TSE sequences and demonstrate its potential for prospective head motion correction in structural imaging. Methods Repeated modules of servo navigators were inserted before each preparation pulse of MPRAGE and 3D‐TSE sequences (before‐prep) for rapid convergence of motion parameter
Matthias Serger   +7 more
wiley   +1 more source

A Simple, Dynamic Geometric Phantom for MRI and CT Reconstruction Pipelines: Beyond Shepp–Logan

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT A customizable, dynamic geometric phantom was developed to bridge the gap between simplistic static phantoms and highly realistic, complex 4D solutions. The phantom enables initial testing, helps detect implementation errors, and supports quantitative evaluation of new dynamic acquisition and reconstruction methods.
Tamás Hakkel   +4 more
wiley   +1 more source

The Association Between Takotsubo Cardiomyopathy and Acute Pericarditis. [PDF]

open access: yesJACC Case Rep
Pizarro de Magalhães B   +7 more
europepmc   +1 more source

Deep Learning‐Based Dynamic Segmentation of the Left Atrium in 4D Flow MRI

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To design a deep learning pipeline for automated, time‐resolved segmentation of the left atrium (LA) from 4D flow MRI data. Methods We studied 100 individuals including 65 patients with atrial fibrillation (AF) and 35 healthy subjects (HS) resulting in 2530 4D flow MRI time‐volumes acquired in different centers and scanners.
Jonas Leite   +16 more
wiley   +1 more source

Feasibility and SNR Performance of Hyperpolarized 129Xe Gas Exchange Imaging Using a Balanced SSFP Sequence

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To develop a balanced SSFP (bSSFP) sequence for pulmonary 129Xe dissolved‐phase imaging based on a previously described double‐echo sequence facilitating separation into red blood cell and membrane signals, to test its feasibility and compare its SNR performance and imaging results to an analogous FLASH sequence.
Agilo L. Kern   +4 more
wiley   +1 more source

Fast Localized Calibration for Spatial‐Spectral Excitation Without Fly‐Back Gradients

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose Standard spatial‐spectral excitation pulses apply a fly‐back gradient between sub‐pulses, limiting, for example, how thin the slices can be (> 4 mm). Without fly‐back gradients, slices can be as thin as 1.7 mm but require a phase calibration for the sub‐pulses with inverted gradients due to system imperfections.
Michael Schär   +3 more
wiley   +1 more source

Leveraging Public Transit for Robotic Deliveries: A Column Generation Approach

open access: yesNaval Research Logistics (NRL), EarlyView.
ABSTRACT Autonomous mobile robots (AMRs) are small, electric, wheeled vehicles that operate at pedestrian speeds. In the last‐mile delivery service considered in this study, a fleet of AMRs is deployed across multiple recharging depots within a service area, from which they depart to perform point‐to‐point deliveries. We consider an operational setting
Yishay Shapira, Mor Kaspi
wiley   +1 more source

Home - About - Disclaimer - Privacy