Ligand-biased ensemble receptor docking (LigBEnD): a hybrid ligand/receptor structure-based approach. [PDF]
Ligand docking to flexible protein molecules can be efficiently carried out through ensemble docking to multiple protein conformations, either from experimental X-ray structures or from in silico simulations.
Abagyan, Ruben +2 more
core +2 more sources
Quality power is a very important factor for the proper functioning of appliances and can be enhanced using shunt active power filters (SAPF). This work demonstrates the hardware implementation of synchronous reference frame (SRF) theory based SAPF. This
Ravinder Kumar +4 more
doaj +1 more source
Evaluation of a shunt active power filter with energy backup capability [PDF]
This paper presents a new Shunt Active Power Filter (SAPF) that is able to compensate current power quality problems and also to serve as energy backup to the loads in case of power outages.
Afonso, João L. +6 more
core +1 more source
A Deep Learning-Based Approach to Characterize Skull Physical Properties: A Phantom Study. [PDF]
We extracted various features from ultrasound signals using skull‐mimicking phantoms (including variation in thicknesses and porosity) and analyzed them using machine learning and deep learning models. The evaluation demonstrated that ML‐ and DL‐trained models could predict the physical characteristics of skull phantoms with reasonable accuracy for ...
Aggrawal D +5 more
europepmc +2 more sources
Modified SOGI based shunt active power filter to tackle various grid voltage abnormalities
Shunt Active Power Filters (SAPF) have been effectively used to compensate the harmonics generated by the non-linear loads. The SAPF’s performance depends on the accurate generation of reference current, which is dependent greatly on the template of ...
Kalpeshkumar Patil, Hiren H. Patel
doaj +1 more source
Comparison of current-source and voltage-source shunt active power filters for harmonic compensation and reactive power control [PDF]
This paper presents the comparison between two three-phase Shunt Active Power Filters (SAPFs), one with Current-Source Inverter (CSI) and the other with Voltage-Source Inverter (VSI), which are used to compensate current harmonics and to ...
Afonso, João L. +5 more
core +1 more source
Improvement of Power Quality Using Optimized Non-Linear SAPF Controller [PDF]
In this paper, the optimized Fuzzy Logic controlled three-phase Shunt Active Power Filters (SAPF) to eliminate harmonics of line current, correct power factor, balanced and unbalanced loads are given. To efficiently operate the system, Ant Colony Algorithm (ACA) optimizes this fuzzy logic controller.
P.M. Balasubram, G. Gurusamy .
openaire +1 more source
Marketing macro environment during the pandemic Covid-19 [PDF]
Without a doubt, COVID-19 is indeed a disease caused by a recently discovered coronavirus strain, a form of a virus known to cause human respiratory infections. On January 24, 2020, the first case of Malaysia with COVID-19 was detected.
Abu Seman, Noor Aslinda +2 more
core
Shunt Active Power Filter – SIMULINK simulation and DSP-based hardware realization [PDF]
2006-2007 > Academic research: refereed > Refereed conference paperVersion of ...
Che, Y, Cheng, KWE, Zhou, F
core +1 more source
Harmonic Mitigation in a Smart Grid Using a PV-Powered Series Active Power Filter [PDF]
The rising integration of photovoltaic PV sources within SMART GRIDS introduces significant challenges related to power quality PQ, especially due to harmonic distortions that can address grid. Stability, high power quality, and optimal efficiency of all
El Ouardi Said +5 more
doaj +1 more source