Results 21 to 30 of about 1,050 (208)
A Review of Control Technique Applied in Shunt Active Power Filter (SAPF) [PDF]
In recent years, electronic transformers and electronic devices (nonlinear loads) have increased. These loads are the source of harmonics (non-sinusoidal and distorted waves) and the interactive force that affects the performance of the power system ...
Ayad Hadi, Ekhlas Thjeel, Ali Nahar
doaj +1 more source
PQ Theory of SAP Filter in Photovoltaic System Connected to Three-Phase Grid and Controlled Nonlinear [PDF]
Currently, we are trying to improve electrical energy in the world. In practice, the use of switching devices is increased in the various applications. Non-linearity of loads has adverse effects on energy efficiency, power factor, etc. This increases the
Kabba A. +3 more
doaj +1 more source
Research on Oscillation Suppression Methods in Shunt Active Power Filter System
The shunt active power filter (SAPF) system oscillation is a massive threat to the security and stability of the power grid. This study classifies SAPF oscillation into two categories according to the difference in mechanisms. The SAPF oscillation in one
Rui Hou +3 more
doaj +1 more source
Experimental Validation of a Current-Source Converter with Reduced Dc-link Operating as Shunt Active Power Filter [PDF]
Nowadays, the majority of electronic equipment behaves as nonlinear loads, introducing power quality problems into the power grid, namely, current harmonics and low power factor. These problems contribute to reduce the efficiency of the
Catia Oliveira +5 more
doaj +1 more source
A Three-Phase Grid-Connected PV System Based on SAPF for Power Quality Improvement [PDF]
This paper proposes a combined system of three-phase four-wire shunt active power filter (SAPF), and photovoltaic generator (PVG), to solve the power quality problems such as harmonic currents, poor power factor, and unbalanced load.
Rachid Belaidi +3 more
core +4 more sources
A fault tolerance method based on switch redundancy for shunt active power filter
In order to improve the reliability of the shunt active power filter(SAPF) system, the fault-tolerant control strategy of the system is studied in this paper.
Dongdong Chen +3 more
doaj +1 more source
. This study presents a straightforward adaptive prefiltering algorithm based on a double second-order generalized integrator with prefilter to solve one of the power quality issues, this algorithm is in charge of the determination of the reference ...
S. Kalkoul +3 more
doaj +1 more source
Quality power is a very important factor for the proper functioning of appliances and can be enhanced using shunt active power filters (SAPF). This work demonstrates the hardware implementation of synchronous reference frame (SRF) theory based SAPF. This
Ravinder Kumar +4 more
doaj +1 more source
Harmonic Mitigation in a Smart Grid Using a PV-Powered Series Active Power Filter [PDF]
The rising integration of photovoltaic PV sources within SMART GRIDS introduces significant challenges related to power quality PQ, especially due to harmonic distortions that can address grid. Stability, high power quality, and optimal efficiency of all
El Ouardi Said +5 more
doaj +1 more source
SAPF for the Inter-harmonics on Grid Network Compensation
Using SAPF (shunt active power filter) has been proved as an effective way for harmonic compensation. In practical applications, the performance of SAPF will be impacted by interharmonics and non-periodic disturbances. This paper analyzed the CPT (conservative power theory) definition of power theory and the application method for SAPF.
Chao Zhang, Yi J. Zhang
openaire +1 more source

