Results 161 to 170 of about 394 (211)

3D‐Mixer‐Assisted High‐Entropy Doping of LiNiO2 for Co‐Free Ni‐Rich Cathodes in Lithium‐Ion Batteries

open access: yesAdvanced Science, EarlyView.
High‐entropy doping of Co‐free Ni‐rich LiNiO2 cathodes is achieved through a scalable 3D mixing process. Multi‐element incorporation stabilizes the layered structure, alleviates Li/Ni disorder and electrode swelling, and enhances cycling stability. This approach underscores the potential of high‐entropy strategies to deliver structurally robust and ...
Seung Ri Kim   +6 more
wiley   +1 more source

ZrO2 Aerogel‐Supported Pd Nanoparticles for Photothermal CO2 Reduction

open access: yesAdvanced Science, EarlyView.
Nanoparticle‐based aerogels are promising catalysts for photothermal reactions due to optical transparency, high surface area, and low thermal conductivity. Here, we present deposition of Pd nanoparticles on ZrO2 aerogel granules by a wet‐impregnation approach.
David Kiwic   +3 more
wiley   +1 more source

Molecularly Engineered Wing‐Shaped Azobenzene Memristors for Logic‐in‐Memory and Edge Visual Intelligence

open access: yesAdvanced Science, EarlyView.
Rational engineering of terminal substituents in symmetric azobenzene‐based molecules enables precise control over conformationally coupled charge‐transfer processes. This design yields tunable nonvolatile resistive memory behaviors, ranging from write‐once‐read‐many‐times (WORM) to rewritable switching.
Yanze Liu   +11 more
wiley   +1 more source

Thermoelectric PANI/TeNWs Fiber Based Microsensor for Passive Temperature and Active Chemical Sensing

open access: yesAdvanced Science, EarlyView.
Continuous wet‐spinning of PANI with TeNWs yields a multifunctional microfiber. Oriented TeNWs impose chain alignment and enhance π‐electron delocalization, boosting the Seebeck coefficient to 59.9 µV K−1 for passive temperature sensing (1 K detection limit), while achieving high pH sensitivity (59.25 mV pH−1) and rapid NH3 response (0.96 s).
Dongmei Xie   +10 more
wiley   +1 more source

High‐Performance Transparent Solid Polymer Electrolyte Based on Copolymer of Deep Eutectic Electrolyte and Methyl Methacrylate for Electrochemical Devices

open access: yesAdvanced Science, EarlyView.
A copolymerization strategy using a polymerizable deep eutectic electrolyte with MMA forms efficient ion‐transport pathways while maintaining excellent transparency. The solid polymer electrolyte simultaneously achieves 17.8 MPa mechanical strength and 1.43 mS cm−1 ionic conductivity, enhancing long‐term cycling stability in Li|LFP batteries and ...
Tingting Chen   +6 more
wiley   +1 more source

NIR‐II Light‐Triggered Electron Flow Initiates Cuproptosis‐Centered Thermoelectric‐Immunotherapy for Breast Cancer

open access: yesAdvanced Science, EarlyView.
A NIR‐II light‐activatable thermoelectric nanoreactor converts surface‐bound Cu2+ into bioactive Cu+ via directed electron flow. This spatiotemporally controlled reduction triggers potent cuproptosis and immunogenic cell death, eradicating primary tumors and, together with aPD‐1 therapy, suppressing metastases while establishing durable immune memory ...
Boyu Yuan   +10 more
wiley   +1 more source

Multi‐Stimuli Responsive Magneto‐Coacervate Droplets for Selective Molecular Enrichment and Programmable Manipulation

open access: yesAdvanced Science, EarlyView.
ABSTRACT Coacervate droplets formed via liquid–liquid phase separation offer unique opportunities as microreactors and delivery vehicles due to their ability to selectively concentrate biomolecules and support biochemical reactions. However, their passive nature severely restricts precise spatial and temporal control, posing barriers to practical ...
Kailang Liu   +6 more
wiley   +1 more source
Some of the next articles are maybe not open access.

Related searches:

Salt-saturated salt solution as a standard system for sorption calorimetry

Thermochimica Acta, 2004
The method of sorption calorimetry allows simultaneous monitoring of water activity and the partial molar enthalpy of mixing of water. The way of calibration of sorption calorimeter affects the accuracy of the data obtained in sorption experiments.
Vitaly Kocherbitov
exaly   +2 more sources

Effects of Exposure to Vapors of Saturated Salt Aqueous Solutions

IEEE Transactions on Components, Hybrids and Manufacturing Technology, 1982
Saturated salt aqueous solutions are used to produce controlled relative humidities in many laboratory tests. Components of the salt are shown to enter the gas phase and, in some instances, to alter surface film characteristics and chemisty. Coupons of Cu were exposed to the vapors of saturated salt aqueous solutions.
R. Schubert, H. Tompkins
exaly   +2 more sources

Home - About - Disclaimer - Privacy