Stereotactic radiosurgery for multiple small brain metastases using gamma knife versus single‐isocenter VMAT: Normal brain dose based on lesion number and size

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The study evaluates rapid linear accelerator (Linac) single isocenter stereotactic radiosurgery (SRS) with Hyperarc for large target numbers. We compared to Gamma Knife (GK), which suffers from long treatment times and investigated causes of differences. Methods Linac SRS and GK treatment plans for patients receiving 18 Gy to the gross
Abram Abdou   +4 more
wiley   +1 more source

National undergraduate surgical learning objectives: the NUSLO project. [PDF]

open access: yesCan J Surg
Al Kaabi N   +14 more
europepmc   +1 more source

Methods for working with problem residents in medical physics residency education

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Medical physics residency training programs may occasionally encounter residents requiring additional intervention beyond normal training efforts. In the literature, these residents are referred to as “problem” residents. While the physician literature on the subject is valuable, this paper specifically focuses on dealing with a problem ...
Christopher J. Watchman, Dandan Zheng
wiley   +1 more source

Assessment of Approaches Promoting Virtual Radiation Oncology Educational Content to Medical Students. [PDF]

open access: yesAdv Radiat Oncol
Mattes MD   +13 more
europepmc   +1 more source

Dosimetric effect of silicone‐based gel on skin surface during volumetric modulated arc therapy for breast cancer

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to quantify and compare the dosimetric effects of varying thicknesses of StrataXRT, a silicone‐based gel, and other topical agents on the skin surface during volumetric modulated arc therapy (VMAT) for breast cancer.
Tenyoh Suzuki   +13 more
wiley   +1 more source

Toward a human‐centric co‐design methodology for AI detection of differences between planned and delivered dose in radiotherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Introduction Many artificial intelligence (AI) solutions have been proposed to enhance the radiotherapy (RT) workflow, but limited applications have been implemented to date, suggesting an implementation gap. One contributing factor to this gap is a misalignment between AI systems and their users.
Luca M. Heising   +11 more
wiley   +1 more source

Development of a generic focal spot measurement method suitable for bore‐type linacs

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose In linear accelerators, deviations in the x‐ray focal spot position significantly affect the accuracy of radiation therapy. However, as the focal spot position in bore‐type linac systems such as the Radixact system, cannot be assessed using conventional methods, a new evaluation method is required.
Hidetoshi Shimizu   +5 more
wiley   +1 more source