Impact of Collimator Material on Spatial Resolution and Sensitivity in Semiconductor-Based Imaging Systems: A Monte Carlo Evaluation. [PDF]
Ghoneim MA, Rashed W.
europepmc +1 more source
Low-Energy Single-Electron Detector with Submicron Resolution. [PDF]
Ixquiac Méndez LA +3 more
europepmc +1 more source
Emulating Clinical Workflow of Scintillator Array Dosimetry for FLASH Pencil-Beam Scanning Proton Therapy. [PDF]
Vasyltsiv R +6 more
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Foggy scintillation counting technique
Applied Radiation and Isotopes, 2001A new "foggy scintillator" was developed for the measurement of low-energy beta-emitters in air. By the use of an ultrasonic wave generator, a liquid scintillator can be converted into the "foggy scintillator". In order to obtain reasonable detection efficiency, it is necessary to prepare a liquid scintillator with a very high concentration of the ...
H, Fujii, M, Takiue
openaire +2 more sources
Fundamentals of scintillation counting
Seminars in Nuclear Medicine, 1973The operation of a scintillator detector depends upon the detection of fluorescent radiation emitted from the phosphor following absorption of ionizing radiation. In organic phosphors this fluorescence takes place at the molecular level. In in-organic phosphors the fluorescence is dependant upon the crystal structure and impurities have to be present ...
openaire +2 more sources
A new scintillator for liquid scintillation counting
The International Journal of Applied Radiation and Isotopes, 1967Abstract This report describes the results of investigations carried out with a new scintillator: 2-(4′-t-Butylphenyl)-5-(4″-biphenylyl)-1,3,4-oxdiazole (Butyl-PBD). Counting efficiencies and background counts of variously quenched toluene and dioxane systems containing Butyl-PBD have been compared with similar systems containing PPO and DM-POPOP as ...
openaire +2 more sources
Scintillation counting equipments
Journal of the Institution of Electrical Engineers, 1951Two types of scintillation counter, employing the VX 5045 multiplier photocell and a phosphor, are described. The alpha scintillation counting equipment is a complete instrument for counting samples of low activity over an area of 10 cm2, at background rates of less than 2 counts per hour.
R.B. Owen, E.A. Sayle
openaire +1 more source
Chemiluminescence in liquid scintillation counting
Analytical Biochemistry, 1970Abstract A new chemiluminescence reaction arising from the combination of trichloroacetic acid and bathophenanthroline during the liquid scintillation counting of the Fe 59 beta emission is described. This is compared to the previously reported chemiluminescence arising from a reaction between quarternary amines and peroxides.
A H, Woods, P R, O'Bar
openaire +2 more sources
Scintillation Counting of Gamma-Rays
Nature, 1950WE have investigated the significance of absolute counting-rate in the scintillation measurement of gamma-rays from radium-226, iodine-131, cobalt-60 and sodium-24.
W V, MAYNEORD, E H, BELCHER
openaire +2 more sources