Results 171 to 180 of about 11,763 (301)
Ultra-dense lutetium oxide ceramic scintillators for positron emission tomography. [PDF]
Hamato A +11 more
europepmc +1 more source
This work presents a compact induction heating system for time‐resolved in situ X‐ray diffraction imaging. The system enables contact‐free volumetric heating up to approximately 1600°C and provides flexible operation in different operating modes. Its performance is demonstrated through representative diffraction imaging experiments.We present a compact
Merve P. Kabukcuoglu +6 more
wiley +1 more source
Intermolecular Aggregation-Induced Delayed Fluorescence Scintillators for Ultrahigh-Resolution X-Ray Imaging. [PDF]
Yuan J +12 more
europepmc +1 more source
Distributed computing for the reconstruction of multi‐terabyte tomographic X‐ray imaging datasets
As tomographic datasets from synchrotrons continue to increase in volume, so rises the challenge of reconstructing said data. Here we present a solution utilizing high‐performance computing capabilities to split the process into multiple smaller tasks, which can be solved without overwhelming a single compute node.
Thorbjørn Erik Køppen Christensen +5 more
wiley +1 more source
Lapped Si(111) crystals in a double‐crystal monochromator provide high‐flux, spectrally pure, and moderate‐bandwidth X‐ray beams at 100 keV, offering a robust and cost‐effective alternative to perfect‐crystal and multilayer optics.Lapping the surfaces of Si(111) crystals in a double‐crystal monochromator significantly increases the intensity of high ...
Hiroshi Yamazaki +3 more
wiley +1 more source
Fluorescent‐target imaging and real‐time beam diagnostics at the High Energy Photon Source
A fluorescent‐target imaging and real‐time beam diagnostic platform has been developed for the High Energy Photon Source (HEPS), integrating synchronized multi‐camera acquisition within the Experimental Physics and Industrial Control System (EPICS) areaDetector framework, online beam‐parameter extraction, and Mamba Data Worker enabled data management ...
Qun Zhang +8 more
wiley +1 more source
First-principles study of rare-earth-free Cs<sub>4</sub>SrI<sub>6</sub>:Tl, a zero-dimensional halide perovskite for scintillation applications. [PDF]
Miah MH +7 more
europepmc +1 more source
The evolution of hierarchical phase‐contrast tomography (HiP‐CT) from its origins at the BM05 beamline to its transition to BM18 (ESRF‐EBS) is shown. The novel hardware and scanning approach developments resulted in significantly improved data quality, resolution, sensitivity and speed.
Hector Dejea +9 more
wiley +1 more source
All-inorganic lattice-contracted fabric image sensors for extreme-temperature radiography. [PDF]
Xu L +7 more
europepmc +1 more source
A robotic and high‐throughput X‐ray micro‐computed tomography workflow
A high‐throughput and automated experimental workflow for synchrotron X‐ray micro‐computed tomography is demonstrated. The system integrates automated robotic sample exchange and data acquisition, enabling large‐scale and data‐driven research.With the recent upgrades of synchrotron facilities and an increasing demand for artificial intelligence (AI ...
Xiaoyang Liu +8 more
wiley +1 more source

