Results 21 to 30 of about 154,622 (219)

Modeling of scroll compressors – Improvements

open access: yesInternational Journal of Refrigeration, 2010
Abstract This paper presents an improvement of the scroll compressors model previously published by Duprez et al. (2007) . This improved model allows the calculation of refrigerant mass flow rate, power consumption and heat flow rate that would be released at the condenser of a heat pump equipped with the compressor, from the knowledge of operating ...
Duprez, Marie-Eve   +2 more
openaire   +1 more source

Modelling of reciprocating and scroll compressors

open access: yesInternational Journal of Refrigeration, 2007
Abstract This paper presents simple and thermodynamically realistic models of two types of compressors widely used in domestic heat pumps (reciprocating and scroll compressors). These models calculate the mass flow rate of refrigerant and the power consumption from the knowledge of operating conditions and parameters.
Duprez, Marie-Eve   +2 more
openaire   +2 more sources

Energy saving in six doors walk-in cooler

open access: yesEnergy Reports, 2020
Two Identical six doors walk-in coolers are installed with the fixed speed compressor and the digital scroll compressor. Both compressors have almost the same cooling capacity of 8 kW at the evaporating temperature of -6.7 °C and the ambient temperature ...
Somchai Pattana   +2 more
doaj   +1 more source

Analysis of 3D Transient Flow in a High-Speed Scroll Refrigeration Compressor

open access: yesEnergies, 2023
In mobile devices such as aircraft and electric vehicles, due to limited space, there are strict requirements on the volume and weight of the compressor mounted on the vehicle.
Xiaoran Li   +5 more
doaj   +1 more source

Experimental evaluation of the effect of leakage in scroll compressor

open access: yesJournal of Thermal Engineering, 2023
This research gives an experimental investigation of the scroll compressor, with an emphasis on the effect of leakage on performance enhancement. The effect of gas leakage losses on com-pressor performance is studied both experimentally and conceptually.
Niyaj Dilavar SHIKALGAR   +1 more
doaj   +1 more source

An Improved Geometric Theoretical Model and Throughflow Prediction Method for a CO2 Scroll Compressor of Automotive Air Conditioning System

open access: yesInternational Journal of Energy Research, 2023
The scroll‐type compressor is the core component of the refrigeration system using the natural refrigerant carbon dioxide. An accurate scroll geometric theoretical model is essential for evaluating and enhancing compressor performance.
Panpan Song   +6 more
semanticscholar   +1 more source

Construction and Analysis of Variable Wall Thickness Profile of Double Scroll Teeth of Scroll Compressor [PDF]

open access: yesE3S Web of Conferences, 2021
Based on the changing trend of the geometric parameters of the scroll profile of the involute of circle with variable radii, a new type of double scroll teeth profile of scroll compressor composed of involute of circle with variable radii is constructed.
Peng Bin   +4 more
doaj   +1 more source

Numerical calculation of scroll compressor geometry and assessment of its delivery

open access: yesFrontiers of Mechanical Engineering, 2023
This paper proposes innovative numerical methods for calculating the chamber volumes and tangential leakage gaps in a scroll compressor, a critical aspect of enhancing its performance and efficiency.
J. Prezelj, N. Cerkovnik
semanticscholar   +1 more source

Consideration of hydrodynamic forces in determining the force factors acting operating elements of a scroll compressor [PDF]

open access: yesОмский научный вестник: Серия "Авиационно-ракетное и энергетическое машиностроение"
Increasing the efficiency of compressor equipment is an important task, the solution of which contributes to the rational use of economic resources and improvement of the environmental situation.
V. A. Pronin   +3 more
doaj   +1 more source

The prospect of using ozone-safe refrigerants with low global warming potential in scroll compressors. Part 1 [PDF]

open access: yesОмский научный вестник: Серия "Авиационно-ракетное и энергетическое машиностроение", 2021
The Montreal Protocol and the Kigali Amendment have determined the need and deadlines of the replacement of hydro fluorinated refrigerants.
V. A. Pronin   +3 more
doaj   +1 more source

Home - About - Disclaimer - Privacy