Results 1 to 10 of about 453,863 (195)
Space Plasma Distribution Effect of Short-Circuit Arc on Generation of Secondary Arc [PDF]
Secondary arc is more severe in the ultra-high voltage (UHV) power grid. However, the mechanism for the generation process of secondary arc at the extinction moment of a short-circuit arc is not yet clear.
Haoxi Cong +4 more
doaj +2 more sources
Electric arc furnace transformer secondary circuit calculations [PDF]
This paper demonstrates a procedure for calculating stress and temperature in the secondary high current circuit of a modern electric arc furnace. At the beginning, the separate parameters that form the electric circuit from the furnace to the ...
Cundeva Snezana, Digalovski Mihail
doaj +2 more sources
A Practical Method for Calculating the Reclosing Time in Long Lines with Reactors Case Study: Transmission Lines of Yazd Province [PDF]
In transmission networks, the recloser is used to detect and interrupt transient faults, isolate faults, manage the network structure, and increase reliability.
hossein dehghan dehnavi
doaj +1 more source
Pattern Recognition Based Auto-Reclosing Scheme Using Bi-Directional Long Short-Term Memory Network
Precise knowledge of secondary arc extinction instant and fault nature (temporary or permanent) is necessary for auto-reclosing after a single line-to-ground fault.
Muhammad Saad +2 more
doaj +1 more source
Adaptive Single-Pole Auto-Reclosing Scheme Based on Secondary Arc Voltage Harmonic Signatures
This paper presents an advanced adaptive single-pole auto-reclosing (ASPAR) scheme based on harmonic characteristics of the secondary arc voltage. For analysis of the harmonics, short-time Fourier transform (STFT), which is a universal signal processing ...
Joon Han, Chul-Moon Lee, Chul-Hwan Kim
doaj +1 more source
Arc ubiquitination regulates endoplasmic reticulum-mediated Ca2+ release and CaMKII signaling
Synaptic plasticity relies on rapid, yet spatially precise signaling to alter synaptic strength. Arc is a brain enriched protein that is rapidly expressed during learning-related behaviors and is essential for regulating metabotropic glutamate receptor ...
Mohammad A. Ghane +14 more
doaj +1 more source
Modelling of Secondary Arc Using EMTP-RV [PDF]
Most of faults occurred in transmission lines are single-phase to ground faults and transient faults. Single-phase auto reclosing is an appropriate scheme to maintain the system stability and restore the system effectively when those faults are occurred.
Yun-Sik Oh +3 more
openaire +1 more source
This review aims to show the significance of the use of secondary carbon bio-carriers for iron and steel production. The term ‘secondary carbon bio-carriers’ in this review paper refers to biomass, torrefied biomass, biochar, charcoal, or biocoke.
Lina Kieush +11 more
doaj +1 more source
Multi-variable dependent forecast algorithm for predicting secondary arc
Hongshun Liu +6 more
doaj +2 more sources
This paper proposes a novel two-stage adaptive reclosing mechanism for shunt-compensated extra-high-voltage transmission lines. In the first stage, secondary arc extinction peak-based criterion (SAEPC) is established to monitor the precise instant of ...
Muhammad Saad, Chul-Hwan Kim
doaj +1 more source