Results 31 to 40 of about 52,412 (170)

Vertical distribution of seismic design load for seismically isolated buildings corresponding to diversity of seismic isolation devices

open access: yesJAPAN ARCHITECTURAL REVIEW, 2012
AbstractThis paper proposes a vertical distribution of seismic design load of seismically isolated buildings corresponding to diversity of seismic isolation devices such as hysteretic dampers and/or velocity‐dependent dampers. This proposed method is obtained from the relationship between response amplification caused by higher‐mode responses and key ...
Masahito Kobayashi   +2 more
openaire   +3 more sources

A Natural Seismic Isolating System: The Buried Mangrove Effects [PDF]

open access: yes, 2011
The Belleplaine test site, located in the island of Guadeloupe (French Lesser Antilles) includes a three-accelerometer vertical array, designed for liquefac- tion studies.
Foray, Pierre   +4 more
core   +5 more sources

Displacement power spectrum measurement of a macroscopic optomechanical system at thermal equilibrium [PDF]

open access: yes, 2006
The mirror relative motion of a suspended Fabry-Perot cavity is studied in the frequency range 3-10 Hz. The experimental measurements presented in this paper, have been performed at the Low Frequency Facility, a high finesse optical cavity 1 cm long ...
Barsotti, L.   +29 more
core   +2 more sources

Seismic Response Analysis of an Isolated Structure with QZS under Near-Fault Vertical Earthquakes

open access: yesShock and Vibration, 2018
Seismic isolation devices are usually designed to protect structures from the strong horizontal component of earthquake ground shaking. However, the effect of near-fault (NF) vertical ground motions on seismic responses of buildings has become an ...
Dewen Liu   +3 more
doaj   +1 more source

Shaking Table Tests of Lead Inserted Small-Sized Laminated Rubber Bearing for Nuclear Component Seismic Isolation

open access: yesApplied Sciences, 2021
To assure seismic isolation performance against design and beyond design basis earthquakes in the nuclear facility components, the lead inserted small-sized laminated rubber bearings (LRB), which has a 10 kN vertical design load, have been designed and ...
Gyeong-Hoi Koo   +2 more
doaj   +1 more source

Evaluating adaptive vertical seismic isolation for equipment in nuclear power plants [PDF]

open access: yes, 2020
Seismic isolation systems are widely recognized as beneficial for protecting both acceleration- and displacement-sensitive nonstructural systems and components.
Becker, TC   +2 more
core  

Hybrid Passive Control Strategies for Reducing the Displacements at the Base of Seismic Isolated Structures [PDF]

open access: yes, 2019
In this paper, the use of hybrid passive control strategies to mitigate the seismic response of a base-isolated structure is examined. The control performance of three different types of devices used for reducing base displacements of isolated buildings ...
Di Matteo A., Masnata C., Pirrotta A.
core   +1 more source

A Study on the Design of a New Three-Dimensional Seismic Isolation Bearing Based on an Improved Genetic Algorithm for Bridge Engineering

open access: yesApplied Sciences
(1) Background: In most cases, passive isolation control methods are commonly used for the seismic isolation design in bridge engineering. However, passive seismic isolation devices, due to their non-adjustable performance parameters, struggle to achieve
Ying Sheng   +3 more
doaj   +1 more source

Dynamic assessment of the seismic isolation influence for various aircraft impact loads on the CPR1000 containment

open access: yesNuclear Engineering and Technology, 2018
An aircraft impact (AI) on a nuclear power plant (NPP) is considered to be a beyond-design-basis event that draws considerable attention in the nuclear field.
Runyu Mei   +3 more
doaj   +1 more source

Geotechnical design with apparent seismic safety factors well-bellow 1 [PDF]

open access: yes, 2014
The paper demonstrates that whereas often in seismic geotechnical design it is not realistically feasible to design with ample factor of safety against failure as is done in static design, an "engineering" apparent seismic factor of safety less than 1 ...
Anastasopoulos   +27 more
core   +3 more sources

Home - About - Disclaimer - Privacy