Results 261 to 270 of about 165,035 (282)
Some of the next articles are maybe not open access.

Greedy Optimization of Sensor Array Geometry for Magnetocardiographic Source Localization

IEEE Transactions on Biomedical Engineering
Until recently, magnetocardiography (MCG) studies were performed using SQUID systems, consisting of a planar array of sensors with uniform spacing. The introduction of optically-pumped magnetometers (OPMs) now enables the deployment of large, conformal arrays, in which the sensors can be mounted on a wearable vest at nearly any location.
Barry Van Veen   +2 more
openaire   +2 more sources

Electronic Nose Sensor Array Optimization Using Rough Set Theory

AIP Conference Proceedings, 2011
The most important component of an electronic nose instrument is the sensor array and its classification accuracy depends significantly upon the choice of the sensors in the array. In many applications of electronic nose, a few sensors are sometimes redundant and only a subset of the sensor array contributes to the decision. Thus, the number of sensors
Rajib Bandyopadhyay   +4 more
openaire   +1 more source

Designing optimal sensor arrays: leveraging hard modeling for improved performance

Microchimica Acta
In a sensor array system with the ability to design multiple sensor elements, selecting the optimal sensor elements can maximize the efficiency of the sensor array in responding to various analytes. This paper proposes the application of hard chemical modeling as a means to identify the optimal subset of indicator displacement assay (IDA)-based sensors
Somaiyeh Khodadadi, Karimvand   +1 more
openaire   +2 more sources

Optimized switching configurations for reconfigurable arrays of sensor elements

The Journal of the Acoustical Society of America, 2008
The reconfigurable ultrasound array disclosed herein is one that allows groups of subelements to be connected together dynamically so that the shape of the resulting element can be made to match the shape of the wave front. This can lead to improved performance and/or reduced channel count. Reconfigurability can be achieved using a switching network. A
openaire   +1 more source

Optimization Methods for Analyte Recognition from Optical Sensor Arrays

2002
Abstract : This project focused on the analysis of an artificial olfactory system. Light at single wavelengths is piped down a doped fiber optic causing the dyes to fluoresce. As chemicals are drawn across the doped fiber optics, they adhere temporarily to the dye and change the color of the fluorescing dye.
openaire   +1 more source

Sensor array current consumption optimizer with Gradient Descent

2023 XXXII International Scientific Conference Electronics (ET), 2023
openaire   +1 more source

Model-based optimization of tunable, biomimetic hair sensor arrays

2008
Crickets have, quite often, been a subject of common interest to biologists and engineers. They have evolved with a pair of special flow-sensitive appendices called cerci with numerous mechano-receptive filiform hairs of different lengths, distributed on the surface.
Jaganatharaja, R.K.   +5 more
openaire   +1 more source

Home - About - Disclaimer - Privacy