Modeling of Severe Plastic Deformation by HSHPT of As-Cast Ti-Nb-Zr-Ta-Fe-O Gum Alloy for Orthopedic Implant. [PDF]
Bîrsan DC +4 more
europepmc +1 more source
Skin‐Interfaced Therapeutic Patches for Wound Fluid Management and Transdermal Drug Delivery
This study presents an integrated skin‐interfaced device combining microfluidics, hydrogel film technology, flexible electronics, and iontophoresis‐based transdermal delivery of PDRN to enhance wound healing. The device effectively manages wound fluid, maintains optimal moisture, and non‐invasively delivers therapeutic drugs.
Dongjun Han +5 more
wiley +1 more source
Manufacturing of Textured Bulk Fe-SmCo5 Magnets by Severe Plastic Deformation. [PDF]
Weissitsch L +7 more
europepmc +1 more source
Continuous Severe Plastic Deformation Methods
GÜNAY BULUTSUZ, ASLI +1 more
openaire +2 more sources
Ti6Al4V‐Bioglass‐Copper Composites for Load‐Bearing Implants
We have designed and manufactured a novel Ti64‐based composite by adding 45S5 bioglass (BG) and copper (Cu). Adding BG on titanium improves wear resistance and biocompatibility, whereas Cu addition improves mechanical strength while providing inherent lifelong bacterial resistance.
Lochan Upadhayay +3 more
wiley +1 more source
Microstructural characterization of Ti-6Al-7Nb alloy after severe plastic deformation
The ASTM F1295/Ti-6Al-7Nb alloy present mechanical properties and biocompatibility very attractive for application in medical and dental implants.
Juno Gallego +7 more
doaj
Investigation of Severe Plastic Deformation Effects on Magnesium RZ5 Alloy Sheets Using a Modified Multi-Pass Equal Channel Angular Pressing (ECAP) Technique. [PDF]
Sahoo PS +5 more
europepmc +1 more source
xx xx. ABSTRACT Osseointegration of orthopedic and dental implants is influenced by local and systemic factors, including their physicochemical surface properties and the patient's overall health status. Titanium and its alloys have been a longstanding standard for bone implants due to their innate biocompatibility and mechanical properties.
Dainelys Guadarrama Bello +2 more
wiley +1 more source
Schematic diagram depicting the fabrication and application of thymosin β4 (Tβ4)‐loaded microneedle patches for wound treatment. The Tβ4 was loaded into chitosan (CS) and sucrose MNs under mild conditions (4°C, 65% relative humidity). The Tβ4 MN patch specifically binds to the downregulated immune regulators Vsig4 and IL22rα2, thereby accelerating ...
Shilong He +4 more
wiley +1 more source
Effects of Severe Plastic Deformation and Ultrasonic Treatment on the Structure, Strength, and Corrosion Resistance of Mg-Al-Zn Alloy. [PDF]
Aksenov DA +7 more
europepmc +1 more source

