Results 91 to 100 of about 19,251 (262)
Development of ± 550 kV DC GIS Basin Insulator
ABSTRACT The basin insulator is a core component of the insulation system for ± 550 kV gas‐insulated switchgear (GIS). This paper, using a finite element method for multi‐physics simulations of electric–thermal coupling, determines a geometry suitable for the industrial production of ± 550 kV GIS basin insulators.
Shaohua Cao +9 more
wiley +1 more source
文中阐述了SF6电气设备中的SF6气体密度下降和微水超标的危害性,并综合分析了SF6电气设备中SF6气体密度和微水监测的现状。为了预防这些危害,提出并研制了SF6电气设备中气体内部微水和密度的在线监测装置,该监测装置通过对SF6气体的循环,实现了内部微水和密度的在线监测,实时了解SF6气室内部水分含量和密度值的变化情况,这对掌握SF6气体的状态,及时预防和排除安全事故,从而保证供电设备的正常运行很有价值。
李秀广 +7 more
doaj
The seasonality of transport and mixing of air into the lowermost stratosphere (LMS) is studied using distributions of mean age of air and a mass balance approach, based on in-situ observations of SF6 and CO2 during the SPURT (Spurenstofftransport in der
Bönisch, Harald +4 more
core +1 more source
Anisotropy in Dry‐Type Valve‐Side Bushings of Converter Transformer: Phenomena and Effects
ABSTRACT The safe and stable working of dry‐type valve‐side bushings, important components of converter transformers, is essential. In recent years, poor design has led to several core breakdown, flashover and cracking failures. The bushing cores, composed of crepe paper and aluminium foil, exhibit significant anisotropic physical properties due to its
Gaoyi Shang +6 more
wiley +1 more source
The occurrence of CF4 and SF6 in natural fluorites (CaF2) is reported. Contents are found to be typically 200–2000 ppt-mass for CF4 and 50–100 ppt-mass for SF6. CF4 and SF6 were also detected in granites where fluorite is an accessory mineral.
Eisenhauer, Anton, Harnisch, J.
core +1 more source
Electrochemical and Infrared Absorption Spectroscopy Detection of SF6 Decomposition Products
Sulfur hexafluoride (SF6) gas-insulated electrical equipment is widely used in high-voltage (HV) and extra-high-voltage (EHV) power systems. Partial discharge (PD) and local heating can occur in the electrical equipment because of insulation faults ...
Ming Dong +4 more
doaj +1 more source
ABSTRACT As a commonly used bushing current‐carrying structure in recent years, contactor‐type electrical connection parts operate in a complex environment of electric, thermal and chemical corrosion for extended periods. With the increase of ultra‐high voltage (UHV) transmission capacity, its operating environment faces more stringent challenges, and ...
Qingyu Wang +9 more
wiley +1 more source
Comparison of Dielectric Recovery After Arc Burning in SF6 Gas and Its Potential Alternatives
ABSTRACT Although sulphur hexafluoride (SF6) exhibits exceptional insulating properties, it is a potent greenhouse gas. Therefore, studying alternatives to SF6 is critical for developing environmentally friendly high‐voltage electrical equipment.
Ziqi Liu +4 more
wiley +1 more source
气体分解产物和局部放电测试技术在SF6电气设备状态诊断中的应用
主要介绍了SF6气体分解产物、局部放电测试这2种检测技术在SF6电气设备状态诊断中的几起成功应用的案例。这些案例各有特点:SF6气体分解产物异常但不存在局部放电信号;SF6气体分解产物正常但存在局部放电信号;SF6气体分解产物异常且存在局部放电信号;SF6气体分解产物异常但无法采用局部放电测试技术进行检测。通过解体,均验证了设备存在缺陷。因此,SF6气体分解产物、局部放电测试技术在SF6电气设备潜伏性故障诊断方面具有广阔的应用前景。
胡红红 +3 more
doaj
The electron drift velocity, longitudinal diffusion and effective ionization coefficients in the gaseous ternary mixtures CF3I-SF6-N2 and CF3I-SF6-CO2 have been measured using a pulsed Townsend apparatus over the density-normalized electric field ...
Hernández Ávila, J. L. +6 more
core +1 more source