Achieving rapid fault clearance in medium-voltage direct current (MVDC) grids requires DC circuit breakers (DCCBs) with high current-interrupting capability and low cost. Our team previously proposed a hybrid DC circuit breaker combining Asymmetric IGCT (
Muhammad Junaid +3 more
doaj +1 more source
ENHANCEMENT OF VOLTAGE SAG & TRANSIENT STABILITY USING RESISTIVE TYPE SFCL FOR FAULT APPEARANCES [PDF]
The proposed structure prevents voltage sag and phase-angle jump of the substation PCC after fault occurrence. This paper proposes a new SFCL structure with a comparison of parallel-LC-resonance type fault current limiter (FCL) that uses a resistor in ...
Gowri, B.Chitti; M.Tech Student Scholar (P.E), Department of Electrical and Electronics Engineering, KITS College of Engineering, Divili, (Affiliated to JNTU Kakinada), A.P, India +1 more
core
Increas demand load and power capacity requirement at PT Pindo Deli then the short circuit current that occur will be greater. this can cause damage to electrical equipment located around the point of interrupting and resulting failure of the electrical ...
Yohanes Sabriant Widyo Utomo +1 more
doaj
Mohammad Reza Barzegar-Bafrooei +1 more
openaire +1 more source
The optimal allocation of H-SFCL in MVDC SPS
Li Zheng +6 more
openaire +1 more source
Temperature Dependent Equivalent Circuit of a Magnetic-Shield Type SFCL
In order to investigate the reciprocal interaction between a SFCL and the Power System an equivalent circuit of the device needs to be introduced in a power system simulator. In this paper the equivalent circuit of a magnetic shield type SFCL, consisting of two coupled electric and thermal networks, is obtained starting from the integral formulation of
FABBRI, MASSIMO +3 more
openaire +2 more sources
The superconducting fault current limiter (SFCL) has been regarded as one of most popular superconducting applications. This article reviews the modern energy system with two major issues (the power stability and fault-current), and introduces ...
Chuanyue Li, Boyang Shen, Yu Chen
exaly +2 more sources
Impact of Copper Stabilizer Thickness on SFCL Performance With PV-Based DC Systems Using a Multilayer Thermoelectric Model [PDF]
Utilizing renewable energy sources (RESs) to their full potential provides an opportunity for lowering carbon emissions and reaching a state of carbon neutrality. DC transmission lines have considerable potential for the integration of RESs.
Xiaoze Pei, Wenjuan Song, Hamoud Alafnan
exaly +2 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Installation and Testing of SFCLs
IEEE Transactions on Applied Superconductivity, 2012A 22.9 kV/630 A-class superconducting fault current limiter (SFCL) was installed on a distribution line in Icheon Substation for real-grid operation. The substation is located in a semi-urban area with moderate loads. The SFCL is of hybrid type. After installation it was subjected to a series of on-site tests.
null Hye-Rim Kim +9 more
openaire +1 more source
Comparative Study of Active SFCL and Resistive type SFCL on a Nine Bus System
2018 International Conference on Computing, Power and Communication Technologies (GUCON), 2018With the increasing load demand and interconnection of distributed generations, there has been a significant rise in short circuit current levels in transmission as well as in distribution networks. The increment in fault current has imposed burden on the existing system equipments and also cause system instability.
Sanchita Kumari, Amrita Sinha
openaire +1 more source