Results 101 to 110 of about 3,158 (247)
The design process of a superconducting current limiter (SFCL) requires simulation and definition of its electrical, magnetic and thermal properties in form of equivalent circuits and mathematical models. However, any change in SFCL parameters: dimension,
H. Heydari, R. Sharifi
doaj
Design of a multifunction novel flexible fault current limiter for AC distribution network. [PDF]
Liu Y +7 more
europepmc +1 more source
In this paper, the combined superconducting fault current limiter (SFCL) and STATCOM are used to improve transient stability and low-voltage ride-through (LVRT) capability of the wind turbine generation system (WTGS).
Atuwo, Tamaraebi
core +1 more source
Synthesized nano particles of glimepiride via spray freezing into cryogenic liquid: characterization, antidiabetic activity, and bioavailability. [PDF]
Gaber DA +6 more
europepmc +1 more source
The continuous evolution of electrical distribution systems—driven by the integration of renewable energy sources and decentralized generation—poses new challenges for grid protection.
Belen Rivera +3 more
doaj +1 more source
Simulation of SI-SFCL for HVDC System: Loss Analysis in System Level
This paper presents a system-level loss study of the saturated iron-core superconducting fault current limiter (SI-SFCL) used in the voltage source converter-based direct current (DC) system.
Yang, J, Coombs, T, ,, Shen, B
core
Comparison between SFCL and TSC for voltage stability enhancement of wind generator system
This work proposes superconducting fault current limiter (SFCL) device to enhance voltage stability of the fixed-speed wind generator system. In order to evaluate the effectiveness of the proposed SFCL methodology in detail, its performance is compared ...
Banik, Arnab +3 more
core +1 more source
Protection of Sensitive Loads in Distribution Systems Using a BSFCL-DVR System. [PDF]
Firouzi M +4 more
europepmc +1 more source
Studi Koordinasi Proteksi Arus Lebih Dengan SFCL (Hybrid Superconducting Fault Current Limiter) di PT. Terminal Teluk Lamong [PDF]
Sistem kelistrikan adalah bagian yang penting dalam suatu perusahaan.Gangguan hubung singkat merupakan gangguan yang paling sering terjadi pada sistem kelistrikan. Besarnya arus gangguan dapat menyebabkan trip di suatu titik area. PT.
Sisna, Avonthea
core
Reclosing operation characteristics of the flux-coupling type SFCL in a single-line-to ground fault
The recloser that is used in distribution systems is a relay system that behaves sequentially to protect power systems from transient and continuous faults.
���������
core +1 more source