Results 11 to 20 of about 29,405 (266)

Short circuit transient power analysis of hybrid intrinsically safe circuit

open access: yesGong-kuang zidonghua, 2023
Currently, research on the intrinsically safe features of intrinsically safe circuits mostly relies on the IEC spark experimental device as the experimental platform.
NIE Honglin   +6 more
doaj   +1 more source

Fast-clamped short-circuit protection of IGBT's [PDF]

open access: yesIEEE Transactions on Industry Applications, 1999
Identification of fault current during the operation of a power semiconductor switch and activation of suitable remedial actions are important for reliable operation of the power converter including the power semiconductor device. A short circuit is a basic and severe fault situation in a circuit structure such as a voltage source converter. This paper
V. John, null Bum-Seok Suh, T.A. Lipo
openaire   +1 more source

Recent Advances in Short Circuit Protection Methods for SiC MOSFET [PDF]

open access: yesMATEC Web of Conferences, 2023
Due to its high efficiency, low switching losses, and high temperature stability, Silicon Carbide (SiC) Metal-Oxide-Semiconductor Field-Effect Transistor (MOSFET) has been widely used in various fields.
Gao Tiecheng
doaj   +1 more source

Short-circuit protection for MV & LVDC grid [PDF]

open access: yes2014 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC), 2014
A DC medium voltage (MV) and low voltage (LV) power distribution network will be proposed and the protection aspects will be discussed in this paper. This paper is mainly focused on the short-circuit overcurrent protection system of the future MV/LVDC distribution network. The proposed MV/LVDC distribution network would be modeled using PSCAD. Positive
Lee, Kok Cheung   +2 more
openaire   +2 more sources

An integrated protection system for mine-used low-voltage feed switch

open access: yesMeikuang Anquan, 2021
A feed switch protection system in the coal mine based on STM32F407 chip is designed. The system has protection functions such as leakage, overcurrent, and short circuit.
TONG Jun, WANG Yue, WU Weidong
doaj   +1 more source

Short-circuit model of the DFIG considering coordinated control strategy of grid- and rotor-side converters

open access: yesEnergy Reports, 2022
The short-circuit current calculation is of vital importance for the power system. With a high proportion of new energy sources, the setting of relay protection and the selection of electrical equipment have been severely degraded.
Fan Xiao   +4 more
doaj   +1 more source

A novel protection strategy for DC microgrid considering communication failure

open access: yesEnergy Reports, 2023
DC microgrid has become an important part of supporting “carbon peaking, carbon neutralization” and building a low-carbon energy system. However, the short-circuit current of the DC microgrid rises rapidly and has a great impact, threatening the normal ...
Weiliang Zhang, Hui Zhang, Na Zhi
doaj   +1 more source

Directional Overcurrent Relays Coordination Problems in Distributed Generation Systems

open access: yesEnergies, 2017
This paper proposes a new approach to the distributed generation system protection coordination based on directional overcurrent protections with inverse-time characteristics.
Jakub Ehrenberger, Jan Švec
doaj   +1 more source

Design and Simulation Analysis of Short Circuit Protection for Electric Ship DC Grid-connected System

open access: yesKongzhi Yu Xinxi Jishu, 2021
DC grid-connection technology is the core technology of electric ship. For a ship DC grid-connected distribution system, when short-circuit occurs in a branch of the system, the short-circuit branch needs to be cut off, and the other branches can be ...
WANG Wei, ZHANG Hanchen
doaj  

A Scheme of DC-side Short-circuit Protection for Bi-directional Converterin Urban Rail Traction Power Supply System

open access: yesKongzhi Yu Xinxi Jishu, 2021
Using bi-directional converters for traction power supply in urban rail transit, traditional PWM rectifiers cannot meet the requirement of DC feeder protection for 27 kA short-circuit current with 120 ms continuous time.
WANG Xiong   +3 more
doaj  