Results 1 to 10 of about 118,427 (167)
The safe operating area is an operating area with high reliability for SiC MOSFET, and its degradation may cause power electronic system failure. The safe-operating-area degradation and the failure modes of 1200 V/66A SiC MOSFET caused by repetitive ...
Ziyang Zhang, Lin Liang, Haoyang Fei
doaj +1 more source
In recent years, the demand for medium and large secondary batteries in EV (electric vehicle) and ESS (energy storage systems) applications has been rapidly increasing worldwide, and accordingly, the market size is increasing exponentially.
Jae-Beom Jung +5 more
doaj +1 more source
With the growing capacity of the distribution network, the probability of short circuit accidents gradually increases. Accidents such as deformation of distribution transformer windings, shift of laminations, fracture and even explosion of mechanical and
Guoju Zhang +4 more
doaj +1 more source
The paper is a continuation of the research works of the authors. The aim of it is identifying the electromagnetic environment in which the control equipment of the short-circuit test stand operates.
Jolanta Sadura +4 more
doaj +1 more source
Analysis of the short-circuit characteristics of SiC metal-oxide-semiconductor field-effect transistors (MOSFETs) is very important for their practical application.
Shen Diao +6 more
doaj +1 more source
Short-circuit test platform can verify the correctness of the distribution network simulation model and the effectiveness of short-circuits protection. It is necessary to simplify the structure of the distribution network into a typical branch and build ...
Guodong Liu, Feng Ji, Wen Sun, Lin Sun
doaj +1 more source
Asymmetric short-circuit fault breaking test T100a is an important test item of High-voltage AC Circuit-breakers. In non-effectively earthed neutral system the first pole to clear factor is 1.5 and the transient recovery voltage (TRV) has two or four ...
HE Ninghui +5 more
doaj +1 more source
Once the short circuit damage accident of a large capacity 500 kV transformer occurs suddenly, it will seriously affect the safe operation of the power grid.
Zhongxiang Li +7 more
doaj +1 more source
Design and application of short circuit test scheme for Hu Zhou DPFC project
The short circuit test of distributed power flow controller (DPFC) is still a blank in the world. In order to test the effectiveness and adaptability of DPFC in case of line failure, it is necessary to carry out short circuit tests in DPFC projects ...
Qian Chen +5 more
doaj +1 more source
This article investigates the application of the pulse voltage method for detecting interturn short-circuit faults in the high-voltage windings of dry-type voltage transformers.
Hongyan Nie +3 more
doaj +1 more source

