Results 21 to 30 of about 10,590,427 (302)
In this work, the vibrations on the surfaces of the tank wall, stiffeners, and the cover of a 5 MVA transformer experimental model were measured during open-circuit and short-circuit transformer tests.
Karlo Petrović +2 more
doaj +1 more source
Design of high-power intrinsically safe power supply based on fault current change rate
In order to solve the problems of low output power, poor protection effect, and slow dynamic response speed of existing intrinsically safe power supply, a high-power intrinsically safe power supply based on fault current change rate is designed.
KANG Qian +3 more
doaj +1 more source
To improve the accuracy of fault location system, several short-circuit tests need to be conducted before being brought into service in autotransformer (AT) feeding systems for high-speed railways in China.
Qing-an Ma, Wei Liu
doaj +1 more source
Thermal Stability Analysis and Design for Electrical Product in Short-Circuit Fault
In short-circuit faults, the thermal stability of the metal conductor is an important factor for electrical products, which directly affects the safe use of the products.
Jing Hao, Jungang Zhou, Yachao Wang
doaj +1 more source
Study on Inter-Turn Short Circuit Test for Distribution Reactor [PDF]
Inter-turn short circuit is a common fault in reactor. In view of the current situation of insufficient condition based maintenance of reactor, an on-line monitoring method suitable for Inter-turn short circuit fault of distribution reactor was proposed in this paper.
Wei Qin, Tiansong Gu, Hongliang Li
openaire +2 more sources
Research of IGBT failure energy transmission and energy shock
As a power switching device, IGBT has many advantages, such as high current density and low saturation voltage and it is widely used in various power engineering fields. However, IGBT is the most important failure part of power converter system. When the
MA Yao +4 more
doaj
Short-Circuit making of medium voltage load break switches using a grid Connected test circuit [PDF]
The load break switch is an important component in the distribution grid. Besides its capability to break load currents reliably, it has to be able to make short-circuit currents according to the IEC 62271 standard. In this paper, the process of making a
Kaveh Niayesh +5 more
core +1 more source
A Hierachical Infrastrucutre for SOC Test Management [PDF]
HD2BIST - a complete hierarchical framework for BIST scheduling, data-patterns delivery, and diagnosis of complex systems - maximizes and simplifies the reuse of built-in test architectures.
Zorian Y. +4 more
core +1 more source
Short-Circuit Tests and Simulations with a SCFCL Modular Assembly
AbstractShort-circuit tests and simulations carried out with a resistive SCFCL modular assembly are presented. Each SCFCL moduleconsistsofaBSCCO2212bulkcoilwithacritical currentofabout520Aat77K.Seriesandparallel connection were tested. In series connection, prospectivecurrent as high as 67 kArms was limited to about 11 kApeak in the first peak.
Sousa, W. T. B. de +6 more
openaire +2 more sources
Research of Aviation Electric Arc and Short Circuit Damage and Protection
Aviation electric arc and short circuit may lead to irreparable loss. It is of great significance to study the harm of aviation electric arc and short circuit and its protection measures.
CAO Tao
doaj +1 more source