Research on a fault current limiter based on variable reactor

open access: yesZhejiang dianli, 2022
With the increase of the power load in power grid, the short circuit level continues to rise, and excessive short-circuit current will do great damage to power equipment and imperil power systems.
GU Yu   +3 more
doaj   +1 more source

Short circuit fault identification and diagnosis analysis of rotor winding for variable speed pumped storage unit

open access: yesEnergy Reports, 2022
Rotor winding short circuit is a frequent fault type of generator unit. Compared with the traditional fixed-speed unit using DC excitation, the three-phase AC excitation structure of the variable speed pumped storage unit is more complicated, and the ...
Qinghui Lu   +5 more
doaj   +1 more source

Symmetrical Loss of Excitation Fault Diagnosis in an Asynchronized High-Voltage Generator

open access: yesEnergies, 2018
As a new type of generator, an asynchronized high-voltage generator has the characteristics of an asynchronous generator and high voltage generator. The effect of the loss of an excitation fault for an asynchronized high-voltage generator and its fault ...
Yanling Lv   +4 more
doaj   +1 more source

Early slight inter-turn short circuit fault diagnosis of axial flux stator coreless permanent magnet motor based on phase difference [PDF]

open access: yesJournal of Hebei University of Science and Technology
Aiming at the problem of early inter-turn short circuit fault of axial flux stator coreless motor, a method for early inter-turn short circuit fault diagnosis and positioning of axial flux stator coreless motor based on the phase difference of zero ...
Xiaoguang WANG   +4 more
doaj   +1 more source

Fault Characteristic Analysis and a Novel Pilot Protection Scheme for Pole-to-Ground Fault in Flexible DC Distribution Network

open access: yesIEEE Access, 2023
Due to the pseudo-bipolar structure of the flexible DC distribution network, the short-circuit current caused by a pole-to-ground fault is weak. The fault characteristics, particularly the steady-state fault characteristics, are not prominent. Therefore,
Hao Qi   +6 more
doaj   +1 more source

The Cable Fault Diagnosis for XLPE Cable Based on 1DCNNs-BiLSTM Network

open access: yesJournal of Control Science and Engineering, 2023
Diagnosing the fault type accurately from a variety of faults is very essential to ensure a stable electricity supply when a short-circuit fault occurs.
Qianyu Wang   +4 more
doaj   +1 more source

An Analytical Short-Circuit Current Calculation Method for Full-Power Wind Turbines under Complete Fault Ride-Through Processes [PDF]

open access: yesDianli jianshe
Accurate calculation of short-circuit current throughout the fault ride-through process of wind turbines is a critical prerequisite for the analysis and control of modern power systems.
YUAN Shuai, XIAO Jiaan, TAO Jun, CUI Haohan, CHAO Pupu, LI Weixing, A Minfu, WANG Liqiang, ZHONG Ming
doaj   +1 more source

Characteristics of Short-Circuit Current in Distribution Network with Doubly-Fed Wind Power System

open access: yesShanghai Jiaotong Daxue xuebao, 2023
The doubly-fed induction generator (DFIG) is connected to the distribution network as a distributed power source, which turns a radial single power supply system into a dual power supply system and changes the topology of the distribution network. When a
XI Xinze, XING Chao, QIN Risheng, HE Tingyi, HE Peng, MENG Xian, CHENG Chunhui
doaj   +1 more source

Interturn short circuit fault diagnosis method of direct-drive permanent magnet synchronous motor based on two-stage PNN

open access: yes河南理工大学学报. 自然科学版
ObjectivesAccurate positioning of early faults is crucial for preventing the deterioration of motor system faults and formulating operation and maintenance strategies after faults.MethodsAiming at the problem that the inter-turn short-circuit fault ...
GAO Caixia, FENG Lingyun, DANG Jianjun
doaj   +1 more source

Influence Mechanism and Suppression Control of the MMC on Short-Circuit Current Under AC Faults

open access: yesIEEE Access, 2020
Modular multilevel converter based high voltage direct current (MMC-HVDC) transmission systems may increase the short-circuit current and affect the AC fault clearing of circuit breakers.
Jian Yang   +3 more
doaj   +1 more source